EUROBLOC
SERVICE MANUAL FOR HOIST
126/212
This document and the information contained herein, is the exclusive property of Verlinde S.A.S. and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Verlinde S.A.S.
Copyright © (2013) Verlinde S.A.S. All rights reserved.
06/2015
Disassembly
1
2
Switch OFF the power supply to the hoist.
Remove the connection box cover (1). Remove the fixing
screws and the wires from the limit switch and extract the limit
switch (2).
Reassembly
1
2
Fit the limit switch (2) carefully in its place, so that the pinion
fits into the gear-rim of the drum. Tighten the fixing screws.
Re-connect the wires. Close the connection box cover (1).
Switch ON the power supply to the hoist and check the proper
functioning of the limit switch.
CAUTION
In many cases it is necessary to readjust the limit switch. Be aware of
incorrect settings during testing the operation.
Adjustment
1
2
All: Lower the hook to approx. 100 mm above the floor.
Black model: Loosen the locking screw (5)
All: Turn the screw “S4” until the limit switch “S4” is just
activated.
All: Test the operation. The downward motion must stop at the
described distance.