CAUTION
In Low Headroom models, the C-dimension depends on the wheel-gauge of the
trolley. See Technical Guide; Dimensions.
7.1.12.4 Maintenance task for hoisting limit switch, hoist frame size: VT1, VT2, VT3, VT4, VT5.
1
2
Check the proper tripping point of all limiting functions.
Check the wiring for loose connections.
Black model: Check that the locking screw (5) is tight.
7.1.13 Hook operated limit switch
7.1.13.1 Hook operated upper limit switch, Frame size: VTs.
Hook operated limit switch has two steps, normal limit switch and extra safety limit switch. In first step limit switch
trips hoisting movement when hook reaches the adjustable lever. Hoisting movement is possible again after
tripping as soon as hook has been lowered from the switching area. The safety switch cuts the main power if
normal switch fails. In this case hoisting or lowering is not possible, until the reason for limit switch failure has been
solved.
1.Hoist
2.Limit switch inside the electric panel
3.Limit switch lever
4.Hook