EUROBLOC
SERVICE MANUAL FOR HOIST
175/212
This document and the information contained herein, is the exclusive property of Verlinde S.A.S. and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Verlinde S.A.S.
Copyright © (2013) Verlinde S.A.S. All rights reserved.
06/2015
Disassembly
1
2
Lower the hook onto a stable working-platform. Pull some
extra rope down from the drum, so that the hook-block is
free. Switch of the power supply to the hoist.
Remove the rope anchorage. Remove the screw (6) and the
washer in order to remove the sleeves (7).
3
4
Remove the screws in order to remove the limit switch (4).
Remove the screw in order to remove the load sensor (3) if
the load sensor must be replaced.
Reassembly
1
2
Assemble the load sensor (3) and secure in place with
screws. Ensure that the ball glued to the sensor must point
upwards.
Install the limit switch (4) on the overload protection frame
using screws.
3
4
Secure the overload device into place with washer and
screws (6).
Install the machinery covers. Switch ON the power supply to
the hoist.