EUROBLOC
SERVICE MANUAL FOR HOIST
208/212
This document and the information contained herein, is the exclusive property of Verlinde S.A.S. and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of Verlinde S.A.S.
Copyright © (2013) Verlinde S.A.S. All rights reserved.
06/2015
TMV003
TMV006
TMV012
1.Display
2. Navigation and confirmation buttons
3.Terminal for the MCA cable
4.Control unit
5.Main sticker
6. EMC filter screw
7.Power board
8.Digital input terminals
WARNING
There are high voltages inside the frequency converter (including
programming switches). Wait for at least three minutes after the supply
voltage has been switched off before any service actions.
Note: The fault codes are explained in the frequency converter-specific manual.
Frequency converter inspection
1
2
Check that all connections are properly and securely fixed.
Check the operation and cleanliness of the cooling fan.
Check the operation mode.
Check error codes if any.