Express
2012-03
Page 25
To connect the batteries use the reverse order.
3.5 Changing the batteries
L
L
L
L
CAUTION:
Risk of burns – Do not come in contact with the acid from the
batteries. See for a good ventilation of the battery compartment.
The battery shall be changed by trained personnel.
The battery can be changed according following
steps:
1. Remove the battery housing from the wheelchair.
2. Remove the battery cover
by loosen the belt
.
3. Disconnect all the wires on the batteries, power
module.
4. Lift the batteries out the battery housing.
5. Place the new batteries in the battery housing.
6. Connect all the wires to the batteries.
7. Replace the battery cover with the belt .
3.6 Tyre changing
L
L
L
L
CAUTION:
There must be no air in the tube before the tyre can be removed.
L
L
L
L
CAUTION:
Risk of damage - If handled improperly, the rim might become
damaged.
Only an expert can guarantee correct assembly. Work not done by your specialist
dealer, would void any warranty claims.
Use only inflating equipment which complies to regulations and indicates the pressure in bar.
We do not accept any liability for damage caused by using inflation equipment or wheels not
supplied by the manufacturer.
L
L
L
L
WARNING:
Risk of injury - Check that the pressure is correct.
L
L
L
L
CAUTION:
Risk of injury - Make sure that no objects, body parts or inner tubes
are pinched between the tyre and the rim when mounting a tyre.
-
Battery
+
+
Battery
-
24
V
30
A
red
red
Black
Bridge