background image

13

Defiant

®

 1975CE Non-Catalytic / Catalytic Woodburning Stove

30005554

ST1180
flue collar heat shield

Sheet 

Metal 

Screws

Sheet 

Metal 

Screws

Flue Collar 

Heat Shield

ST1180

Fig. 17

  Install flue collar heat shield.

Air Deflector

Air Deflector

waRNiNg:

 The flue collar heat shield must be installed 

in all vertical installations. The flue collar heat shield is 

not used when the flue collar is in the rear exit position.

assemble the Removable insert handle

The ceramic removable insert handle opens and closes 

the front doors. Remove after each use, and store it in 

the  handle  holder  behind  the  right  front  leg.   Assemble 

the handle by passing the 3

³⁄₈

" screw through the ceramic 

shaft and into the bright metal nub. (Fig. 19) Tighten care-

fully until snug. 

ST540

Assembly

handle

11/00

ST540

Fig. 19

  Assemble the front door handle.

ST635

Encore

Install thermostat

handle

2/01

ST635

Fig. 18

  Attach the thermostat handle.

Fan kit installation

1.  Attach the fan assembly at the bottom edge of the in-

ner back with two () 1/4-0 x 3/4” hex head screws.

.  Attach snapstat to the mounting holes on the underside 

of the bottom with two () 1/4-0 pan head screws.

3.  Attach  the  rheostat  holder  (provided  with  the  stove) 

under the right front wing of the bottom heat shield with 

two () #10 sheet metal screws.

4.  Attach the rheostat to its holder by inserting the rheo-

stat  control  shaft  through  the  holder  hole.  Install  the 

retaining ring and rheostat knob onto the shaft.

5.  Secure the rheostat cable to the underside of the bot-

tom  heat  shield  using  the  wire  tie  provided  and  the 

hole at the right rear edge of the heat shield.

6.  Fan will not operate until stove reaches approximately 

43° C (109° F).

7.  Plug  blower  cord  into  a  grounded  outlet.  Do  not  re-

move  ground  prong  from  plug.  Route  power  cord  to 

avoid  heat  from  the  stove  or  other  damage.  Do  not 

route cord under or in front of appliance.

Fig. 20

  Fan installation (Kit # FK6).

34
FANINSTALL

Rheostat 

Knob

Rheostat

Snapstat

Screws

ST848

Hole for Wire  

Tie to Secure 

Cable

Rheostat 

Holder

Summary of Contents for 1975CE CE

Page 1: ...ined a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Contact local buil...

Page 2: ...Vermont Castings stove has been made with the utmost care and will provide you with many years of service As you become acquainted with your new stove you will find that its appearance is matched by...

Page 3: ...missions 13 O2 Catalyst 08 noncat 48 Loading Front and top Chimney connector for 8 flue collar 203 mm 8 diameter for 6 flue collar 152 mm 6 diameter Chimney flue size for 8 flue collar 203 mm 8 minimu...

Page 4: ...house fire Followallinstructions exactly and do not allow makeshift compromises to endanger property and personal safety all local regulations including those referring to na tional and European stan...

Page 5: ...masonry chimney with a nominal flue size of 203 x 203 mm 8 x 8 or 203 x 305 mm 8 x 12 and into a round flue with nominal flue size of 203 mm 8 A Defiant with a 152 mm 6 flue collar is approved for ve...

Page 6: ...efiant is equipped with the 203 mm 8 flue collar an oval to round adapter will be needed Double wall oval to round adapters are available from some manufacturers Your local dealer can help you select...

Page 7: ...ney connector to the outer end of the sleeve with sheet metal screws ST243 thinble connection 12 13 99 djt Thimble Sleeve Chimney Connector Flue Keep sleeve end flush with flue tile ST243 Fig 6 The th...

Page 8: ...through in your installation check with your building inspector before you begin Also check with the chimney connector manufacturer for any specific requirements Accessories are available for use as...

Page 9: ...ve and its connector and nearby combustibles Clearance is the distance between either your stove mea sured from the bottom edge of the stove s top plate or chimney connector and nearby walls floors th...

Page 10: ...nry other than to allow safe access to the controls of the stove For this reason minimum side clearances of 125 mm and a minimum rear clearance of 50 mm are recommended Summary of Clearances Minimum r...

Page 11: ...t Shield Elevation With Shield a t l e a s t 3 x D at least 1 5 x D at least 1 5 x D Plan Without Shield Plan With Shield Air space of at least 12 mm between noncombustible shield and combustible mate...

Page 12: ...ar of the stove The unpainted side must face up towards the stove 3 Pass all four bolts through the large end of the keyholes and then pulling the shield forward to engage the smaller ends of the keyh...

Page 13: ...Installation 1 Attach the fan assembly at the bottom edge of the in ner back with two 2 1 4 20 x 3 4 hex head screws 2 Attach snapstat to the mounting holes on the underside of the bottom with two 2 1...

Page 14: ...e inner cover by pulling it straight out Fig 22 3 Remove the catalyst by gently pulling it straight out Fig 23 Place the catalyst where the catalyst s ce ramic components will not be damaged ST1187 re...

Page 15: ...atic thermostat to ensure an even heat output at whatever manual setting you select The thermostat senses the heating and cooling of the stove surface and adjusts the air shutter accordingly A Damper...

Page 16: ...king or the fire may go out if the fire dies down immediately as a result of the damper being closed Once the combustor starts working heat generated by burning the smoke will keep it working To deter...

Page 17: ...e the ash pan making sure to keep it level To keep the cover from sliding off and to keep ash from falling on the floor do not tilt the ash pan forward If the stove is in operation close the ash door...

Page 18: ...ue that accumulates on the glass surface should be removed regularly to prevent etching To clean the glass follow this procedure Be sure the glass is completely cool Clean the glass with water or a cl...

Page 19: ...spot Continuetomake small adjustments until the setting is right If additional adjusting of the latch does not enable the door to seal sufficiently in one area try adjusting the gasket in that area Pa...

Page 20: ...nless the involved parts are disassembled and then put back together If this is the case the job should be done only by a qualified service technician 5 16 diameter gasket seals the following parts Th...

Page 21: ...and replace if necessary Remove ashes from the ash pan and replace with a moisture absorbing material such as kitty litter to keep the interior of the stove dry Clean the dust from the inner sides of...

Page 22: ...ot If this test indicates a problem consider other possible fac tors as well such as the weather or a change in the quality of your fuel In warm weather draft is weaker than it is in colder winter wea...

Page 23: ...as fast it is likely that the performance change was caused by fly ash deposits on the catalytic element However continue the inspections of the chimney system for a few weeks to ensure that proper pe...

Page 24: ...Defiant Noncatalytic Catalytic Woodburning Stove 9 80 21 20 17 19 16 18 10 11 2 13a 14 15 13b 63 58 32 59 3 36 29 81 39 40 47 38 12 45 37 31 50 51 52 55 70 69 64 68 62 74 72 61 71 69 65 67 74 72 62 30...

Page 25: ...Ashlip See Chart Pg 26 41 Gasket Fireback 30005209 42 Refractory Fireback 30005203 43 Retainer Inner Cover Refractory 30005248 44 Refractory Inner Cover 30005205 45 Andiron 30002827 46 Refractory Acce...

Page 26: ...the firebox should be replaced with stainless steel for ease of future disassembly Defiant Noncatalytic Catalytic Woodburning Stove Model 1975CE continued Shell Enamel Parts Defiant Model 1975 Brown P...

Page 27: ...2 Proof of original purchase date 3 Date of failure of catalyst 4 Any relevant information or circumstances regarding determina tion of failure 5 In addition the owner must return the failed catalyst...

Page 28: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...