warranty 

limited 3 year warranty

MhSc warrants that this woodburning stove will be free of defects 

in material and workmanship for a period of three years from the 

date you receive it, except that the catalyst, thermostat assembly, 

handles, glass door panels, cement, and gasketing shall be war-

ranted as described below.

MHSC will repair or replace, at its option, any part found to be defective 

upon inspection by a Vermont Castings, Authorized  Dealer.  The cus-

tomer must return the defective part or the stove, with shipping prepaid, 

to the Authorized Dealer or pay for any Authorized Dealer in-home 

travel fees or service charges for in-home repair work.  It is the dealer’s 

option whether the repair work will be done in the customer’s home or 

in the dealer’s shop. If, upon inspection, the damage is found to be the 

fault of the manufacturer, repairs will be authorized at no charge to the 

customer for parts and/or labor.
Any woodburning stove or part thereof that is repaired or replaced 

during the limited warranty period will be warranted under the terms of 

the limited warranty for a period not to exceed the remaining term of the 

original limited warranty or six (6) months, whichever is longer.

limited 1 year warranty

The following parts of the woodburning stove are warranted to be free 

of defects in material and workmanship for a period of one year from 

the date you receive it:  The thermostat assembly, handles, glass door 

panels, cement, and gasketing.  Any of these items found to be defec-

tive will be repaired or replaced at no charge, upon the return of the 

part with postage prepaid to a Vermont Castings Authorized Dealer.
Any part repaired or replaced during the limited warranty period will 

be warranted under the terms of the limited warranty for a period not 

to exceed the remaining term of the original limited warranty or six (6) 

months, whichever is longer.

limited catalyst warranty

The catalyst will be warranted for a six year period as follows:  If the 

original catalyst or a replacement catalyst proves defective or ceases to 

maintain 70% of its particulate emission reduction activity (as measured 

by an approved testing procedure) within 4 months from the date the 

stove is received, the catalyst itself will be replaced free.  
From 5 - 7 months a pro-rated credit will be allowed against a re-

placement catalyst and the cost of labor necessary for its installation at 

the time of replacement.
For stove purchases made after June 30, 1990, a third year  

(5 - 36 months) of no charge replacement will be made when combus-

tor failure is due to thermal degradation of the substrate (crumbling of 

ceramic material).  The customer must pay for any in-home travel fees, 

service charges, or transportation costs for returning the stove to the 

Authorized Dealer.
 

Amount of Time 

Credit Towards 

 

Since Purchase 

Replacement Cost

 

0 - 4 months 

100%

 

5 - 36 months 

  50 %

 

37 - 48 months 

  30%

 

49 - 60 months 

  0%

 

61 - 7 months 

  10%

Any replacement catalyst will be warranted under the terms of the 

catalyst warranty for the remaining term of the original warranty.  The 

purchaser must provide the following information in order to receive a 

replacement catalyst under the terms of this limited warranty:

1.  Name, address and telephone number.

.  Proof of original purchase date.

3.  Date of failure of catalyst.

4.  Any relevant information or circumstances regarding determina-

tion of failure.

5.  In addition, the owner must return the failed catalyst.

exclusions & limitations

1.  This warranty is transferable; however, proof of original retail pur-

chase is required.

.  This warranty does not cover misuse of the stove.  Misuse includes 

overfiring which will result if the stove is used in such a manner as 

to cause one or more of the plates to glow red.  Overfiring can be 

identified later by warped plates and areas where the paint pigment 

has burned off.  Overfiring in enamel fireplaces is identified by bub-

bling, cracking, chipping and discoloration of the porcelain enamel 

finish.  MHSC offers no warranty on chipping of enamel surfaces. 

Inspect your woodburning stove prior to accepting it for any damage 

to the enamel.

3.  This warranty does not cover misuse of the stove as described 

in the Owner’s Guide, nor does it cover an stove which has been 

modified unless authorized by a MHSC representative in writing.  

This warranty does not cover damage to the stove caused by burn-

ing salt saturated wood, chemically treated wood, or any fuel not 

recommended in the Owner’s Guide.

4.  This warranty does not cover a stove repaired by someone other 

than a Vermont Castings Authorized Dealer.

5.  Damage to the unit while in transit is not covered by this warranty 

but is subject to a claim against the common carrier.  Contact 

Vermont Castings Authorized Dealer from whom you purchased 

your stove or MHSC if the purchase was direct.  (Do not operate the 

stove as this may negate the ability to process the claim with the 

carrier.)

6.  Claims are not valid where the installation does not conform to local 

building and fire codes or, in their absence, to the recommendations 

in our Owner’s Guide.

7.  The salt air environment of coastal areas, or a high-humidity en-

vironment, can be corrosive to the porcelain enamel finish. These 

conditions can cause rusting of the  cast iron beneath the porcelain 

enamel finish, which will cause the porcelain enamel finish to flake 

off. This warranty does not cover damage caused by a salt air or 

high-humidity environment. 

8.  MHSC shall have no obligation to enhance or update any unit once 

manufactured.

IN NO EVENT SHALL MHSC BE LIABLE FOR INCIDENTAL AND CON-

SEQUENTIAL DAMAGES. ALL IMPLIED WARRANTIES, INCLUDING 

THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS, 

ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. 

THIS WARRANTY SUPERCEDES ALL OTHER ORAL OR WRITTEN 

WARRANTIES.
Some states do not allow the exclusion or limitations of incidential and 

consequential damages or limitations on how long an implied warranty 

lasts, so the above limitations may not apply to you. This warranty gives 

you specific rights and you may have other rights which vary from state 

to state.

how to obtain Service

If a defect is noted within the warranty period, the customer should 

contact a Vermont Castings Authorized Dealer or MHSC if the purchase 

was direct with the following information:

1.  Name, address, and telephone number of the purchaser.

.   Date of purchase.

3.   Serial number from the label on the back.

4.   Nature of the defect or damage.

5.  Any relevant information or circumstances, e.g., installation, 

mode of operation when defect was noted.

A warranty claim will then start in process.  MHSC reserves the right to 

withhold final approval of a warranty claim pending a visual inspection 

of the defect by authorized representatives.

Summary of Contents for 1975CE CE

Page 1: ...ined a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Contact local buil...

Page 2: ...Vermont Castings stove has been made with the utmost care and will provide you with many years of service As you become acquainted with your new stove you will find that its appearance is matched by...

Page 3: ...missions 13 O2 Catalyst 08 noncat 48 Loading Front and top Chimney connector for 8 flue collar 203 mm 8 diameter for 6 flue collar 152 mm 6 diameter Chimney flue size for 8 flue collar 203 mm 8 minimu...

Page 4: ...house fire Followallinstructions exactly and do not allow makeshift compromises to endanger property and personal safety all local regulations including those referring to na tional and European stan...

Page 5: ...masonry chimney with a nominal flue size of 203 x 203 mm 8 x 8 or 203 x 305 mm 8 x 12 and into a round flue with nominal flue size of 203 mm 8 A Defiant with a 152 mm 6 flue collar is approved for ve...

Page 6: ...efiant is equipped with the 203 mm 8 flue collar an oval to round adapter will be needed Double wall oval to round adapters are available from some manufacturers Your local dealer can help you select...

Page 7: ...ney connector to the outer end of the sleeve with sheet metal screws ST243 thinble connection 12 13 99 djt Thimble Sleeve Chimney Connector Flue Keep sleeve end flush with flue tile ST243 Fig 6 The th...

Page 8: ...through in your installation check with your building inspector before you begin Also check with the chimney connector manufacturer for any specific requirements Accessories are available for use as...

Page 9: ...ve and its connector and nearby combustibles Clearance is the distance between either your stove mea sured from the bottom edge of the stove s top plate or chimney connector and nearby walls floors th...

Page 10: ...nry other than to allow safe access to the controls of the stove For this reason minimum side clearances of 125 mm and a minimum rear clearance of 50 mm are recommended Summary of Clearances Minimum r...

Page 11: ...t Shield Elevation With Shield a t l e a s t 3 x D at least 1 5 x D at least 1 5 x D Plan Without Shield Plan With Shield Air space of at least 12 mm between noncombustible shield and combustible mate...

Page 12: ...ar of the stove The unpainted side must face up towards the stove 3 Pass all four bolts through the large end of the keyholes and then pulling the shield forward to engage the smaller ends of the keyh...

Page 13: ...Installation 1 Attach the fan assembly at the bottom edge of the in ner back with two 2 1 4 20 x 3 4 hex head screws 2 Attach snapstat to the mounting holes on the underside of the bottom with two 2 1...

Page 14: ...e inner cover by pulling it straight out Fig 22 3 Remove the catalyst by gently pulling it straight out Fig 23 Place the catalyst where the catalyst s ce ramic components will not be damaged ST1187 re...

Page 15: ...atic thermostat to ensure an even heat output at whatever manual setting you select The thermostat senses the heating and cooling of the stove surface and adjusts the air shutter accordingly A Damper...

Page 16: ...king or the fire may go out if the fire dies down immediately as a result of the damper being closed Once the combustor starts working heat generated by burning the smoke will keep it working To deter...

Page 17: ...e the ash pan making sure to keep it level To keep the cover from sliding off and to keep ash from falling on the floor do not tilt the ash pan forward If the stove is in operation close the ash door...

Page 18: ...ue that accumulates on the glass surface should be removed regularly to prevent etching To clean the glass follow this procedure Be sure the glass is completely cool Clean the glass with water or a cl...

Page 19: ...spot Continuetomake small adjustments until the setting is right If additional adjusting of the latch does not enable the door to seal sufficiently in one area try adjusting the gasket in that area Pa...

Page 20: ...nless the involved parts are disassembled and then put back together If this is the case the job should be done only by a qualified service technician 5 16 diameter gasket seals the following parts Th...

Page 21: ...and replace if necessary Remove ashes from the ash pan and replace with a moisture absorbing material such as kitty litter to keep the interior of the stove dry Clean the dust from the inner sides of...

Page 22: ...ot If this test indicates a problem consider other possible fac tors as well such as the weather or a change in the quality of your fuel In warm weather draft is weaker than it is in colder winter wea...

Page 23: ...as fast it is likely that the performance change was caused by fly ash deposits on the catalytic element However continue the inspections of the chimney system for a few weeks to ensure that proper pe...

Page 24: ...Defiant Noncatalytic Catalytic Woodburning Stove 9 80 21 20 17 19 16 18 10 11 2 13a 14 15 13b 63 58 32 59 3 36 29 81 39 40 47 38 12 45 37 31 50 51 52 55 70 69 64 68 62 74 72 61 71 69 65 67 74 72 62 30...

Page 25: ...Ashlip See Chart Pg 26 41 Gasket Fireback 30005209 42 Refractory Fireback 30005203 43 Retainer Inner Cover Refractory 30005248 44 Refractory Inner Cover 30005205 45 Andiron 30002827 46 Refractory Acce...

Page 26: ...the firebox should be replaced with stainless steel for ease of future disassembly Defiant Noncatalytic Catalytic Woodburning Stove Model 1975CE continued Shell Enamel Parts Defiant Model 1975 Brown P...

Page 27: ...2 Proof of original purchase date 3 Date of failure of catalyst 4 Any relevant information or circumstances regarding determina tion of failure 5 In addition the owner must return the failed catalyst...

Page 28: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...