VENTING INSTALLATION
INSTALLATION PRECAUTIONS
Consult local building codes before beginning the installa-
tion. The installer must make sure to select the proper vent
system for installation. Before installing vent kit, the installer
must read this insert manual and vent kit instructions.
Only a qualified installer/service person should install vent
-
ing system. The installer must follow these safety rules:
•
Wear gloves and safety glasses for protection.
•
Use extreme caution when using ladders or when
on rooftops.
•
Be aware of electrical wiring locations in walls and
ceiling.
The following actions will void the warranty on your vent-
ing system:
•
Installation of any damaged venting component.
•
Unauthorized modification of the venting system.
•
Installation of any component part not manufactured
or approved by Vermont Castings Group.
•
Installation other than permitted by these instruc-
tions.
NOTICE
Failure to follow these instructions will void the
warranty.
VENTING REQUIREMENTS
•
The exhaust vent must reline the entire length of
chimney and terminate above chimney top.
•
Vent must meet all vent manufacturer's requirements
when installed.
•
Make sure you have the following before installing
unit:
•
3" and 3" UL 1777 Listed gas liner for air inlet and
exhaust.
•
Vertical Terminations kits: HEDV32T812,
HEDV32T1212, HEDVRT, AI31TK33A
FP1922
vent requirements
9/08
Maximum Height 40'
(12.9 m)
Minimum Height 10'
(3 m)
Exhaust
Inlet
FP1922
WARNING
• Make sure the exhaust pipe on heater connects to
exhaust portion of cap. Attach flex liners. Figure 6
• Do not crimp or rupture liner when bending it into
chimney offsets.
WARNING
Read all instructions completely and thoroughly before
attempting installation. Failure to do so could result in
serious injury, property damage or loss of life. Operation
of improperly installed and maintained venting system
could result in serious injury, property damage or loss
of life.
WARNING
This insert must be vented to the outside. The venting
system must NEVER be attached to a chimney serving
a separate solid fuel burning appliance. Each gas
appliance must use a separate vent system. Do not use
common vent systems.
Figure 6