16
20306755
30ILDV Series Gas Fireplace Insert
CHECKING GAS PRESSURE
1. Check gas type. The gas supply must be the same as
stated on the appliance’s rating decal. If the gas supply
is different from the fireplace, STOP! Do not install the
appliance. Contact your dealer immediately.
2. Install and attach flex line provided with on this appliance
to 1/2" gas line.
3. After completing gas line connection, purge air from
gas line and test all gas joints from the gas meter to the
fireplace for leaks. Use a soap and water solution or a
gas sniffer.
4. To adjust flame height, turn HI/LO knob to HI to get
maximum pressure to burner. Turn HI/LO knob to LO
to get minimum pressure.
5. To check gas pressures at valve, turn captured screw
counter clockwise 2 or 3 turns and then place tubing
to pressure gauge over test point. Turn unit to high.
Figure 13.
After taking pressure reading, be sure and
turn captured screw clockwise firmly to reseal. Do not
over torque. Check test points for gas leaks with a soap
and water solution or an electronic gas leak detector.
FP1932
valve regulator with knobs
Pressure
Test "IN"
Pressure Test
"OUT"
HI/LO Knob
Pilot Adjustment Screw
FP1932
Figure 13 -
Gas Pressure Check at Gas Valve
ELECTRICAL WIRING
This insert will work without any electrical supply. Elec-
tricity is only needed to operate blower.
Verify proper operation after servicing.
Label all wires before disconnecting when servicing
controls. Wiring errors can cause improper and
dangerous operation.
CAUTION
WARNING
Do not use open flame to check for gas leaks.
WARNING
Electrical connections should only be performed by a
qualified, licensed electrician. Main power must be off
when connecting to main electrical power supply or
performing service. All wiring shall be in compliance
with all local, city and state codes. The appliance, when
installed, must be electrically grounded in accordance
with local codes, or in the absence of local codes, with
the National Electrical Code ANSI/NFPA 70 (latest
edition) and Canadian Electrical Code, CSA C22.1.
INSERT INSTALLATION