25
20306755
30ILDV Series Gas Fireplace Insert
ADJUST THE AIR SHUTTER
The venturi of the burner is equipped with an air shutter.
The opening of the venturi has been set at 1/4" for Natural
Gas and fully open for Propane installation at sea level.
The burner on Natural Gas models may be adjusted for
high altitude as follows:
•
To increase air mixture, open the shutter more. This
will reduce soot formation.
Figure 27
•
To decrease air mixture, close the shutter. Flames
will be more yellow.
Figure 28
FP1940
air shutter part open
Air Shutter
Figure 27 -
Push Adjustment Lip Up to Open Air Shutter
FP1941
air shutter fully open
Air Shutter
Figure 28 -
Pull Adjustment Lip to Close Air Shutter
FP1939
fan control knob
ADJUSTING BLOWER SPEED
The internal blower helps transfer heat from heater into room.
It will not turn on until heater is up to temperature (approxi-
mately 10 minutes after starting).
To turn blower off, turn knob all the way counterclockwise
. One click clockwise turns blower to high speed. Turn-
ing knob clockwise
from high position decreases speed
of blower.
Figure 26
Figure 26 -
Blower Knob
OPERATING INSTRUCTIONS