CFDV Series Gas Fireplace
20306739
33
OPERATING INSTRUCTIONS – MILLIVOLT
PILO
T
OF
F
P
IL
O
T
ON
Continued on next page
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
•
Soap and water solution
•
An approved leak testing spray
•
Electronic sniffer
NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.
1. Depress and turn knob counterclockwise
to
pilot position.
2. Depress fully and hold pilot gas knob. Depress
piezo igniter as many times as needed to ignite pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
LIGHTING PILOT
Pilot Position
Check for gas leaks in each of the following locations:
•
Pipe from the gas supply line connection to the gas valve
•
Burner connections
•
Field made joints / gas shutoff valve
•
Pilot
•
Factory made joints
•
Each joint or connection
•
All joints on valve and control body
LIGHTING PILOT FOR THE FIRST TIME
W
ARNING
If using a soap and water solution
to test for leaks, DO NOT spray
solution onto control body.
DANGER
Never check for gas leak with open
fl ame!
W
ARNING
The control has an interlock device that does not allow the lighting of the fi replace up to the
moment the safety device of the fl ame has not interrupted the gas fl ow. After that period of
time (when the magnet is closed), it is possible to start the lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools during this
operation. Damaged knobs may result in serious injury.