12
20306757
CSDV Series Direct Vent Gas Stove
VENTING INSTALLATION
INSTALLING A VENT SYSTEM IN AN
OUTSIDE CHASE
A chase is a vertical boxlike structure built to enclose
venting that runs along the outside of a building. A chase
is required for such venting.
NOTE:
When installing in a chase, you should insulate the
chase as you would the outside walls of your home. This is
especially important in cold climates. Minimum clearance
between vent pipes and combustible materials such as
insulation is 1".
W
ARNING
Never run the vent pipe level or downward.
This may cause excessive temperatures
which could cause a fire.
W
ARNING
Always maintain minimum clearances
around vent systems. The minimum
clearances to combustibles for horizontal
vent pipe are 2" at the top and 1" at the
sides and bottom of the vent system. For
wall firestops, a 1" minimum clearance all
around the pipe must be maintained. Do not
pack the open air spaces with insulation
or other materials. This could cause high
temperatures and may present a fire hazard.