CSDV Series Direct Vent Gas Stove
VENTING INSTALLATION
VO584-100
9
1
⁄
2
"
(241 mm)
9
1
⁄
2
"
(241 mm)
Vent Opening for Combustible Walls
Framing Detail
Vent Opening for Noncombustible Wall
7
1
⁄
2
"
(190 mm)
VO584-100
Vent Opening
2/99 djt
Figure 15 -
Locate Vent Opening on Wall
HOT
FP1955
horizontal vent cap
Vent Cap
Wood Screw
Apply Mastic to
All Four Sides
Figure 16 -
Install Horizontal Vent Cap
FP1955
HOT
FP1956
vinyl siding standoff
Apply Mastic to
All Four Sides
Cut Vinyl Siding
Away to Fit Standoff
Wood
Screw
Vent
Cap
Bolt
Nut
Standoff
FP1956
Figure 17 -
Install Vinyl Siding Standoff
WARNING
Do not recess vent termination into any wall.
This will cause a fire hazard.
non-hardening mastic around outside edge of the standoff
instead of the vent cap assembly. Use wood screws pro-
vided to attach the standoff.
Figure 17
NOTE:
Replace the wood screws with appropriate fasteners
for stucco, brick, concrete, or other types of siding.
5. Slide the wall thimble over the vent pipe before con-
necting the horizontal run to the vent cap.
Figure 18
6. Carefully move the stove with vent assembly attached
toward the wall and insert the vent pipe into the hori-
zontal termination. The pipe overlap should be a min
-
imum of 1
1
⁄
4
" (32 mm). Apply silicone to the outer pipe
connection. Fasten all vent connections with screws
provided.
7. Slide the wall thimble against the interior wall surface
and attach with screws.
Figure 18
FP1957
install firestop
Interior Wall
Surface
Decorative
Wall Thimble
Horizontal
Vent Pipe
Screw
Vent Cap
(Horizontal
Termination)
FP1957
Figure 18 -
Connect Vent Cap with
Horizontal Vent Pipe
HORIZONTAL TERMINATION
CONFIGURATIONS
Figures 19 through 21
show different configurations for
venting and horizontal termination. Each figure includes a
chart with an example of horizontal maximum and vertical
minimum dimensions taken from the chart on
Page 14
.
NOTE:
The horizontal run controls the mini
-
mum vertical height (i.e. the longer the hori-
zontal run, the higher the termination will be).
Follow the chart on
Page 14
. All horizontal terminations
require a 1/4" (6 mm) rise per 12" (305 mm) of horizontal
run.