background image

- 3 -

LOCATING YOUR 

MAJESTIC

ELECTRIC FIREPLACE

INSTALLATION INSTRUCTIONS

16. This appliance has hot and arcing or sparking parts

inside. Do not use it in areas where gasoline, paint or
flammable liquids are used or stored.  This fireplace
should not be used as a drying rack for clothing, nor
should Christmas stockings or decorations be hung in
the area of it.

17. Use this appliance only as described in this manual.

Any other use not recommended by the manufacturer
may cause fire, electric shock or injury to persons.

18. Avoid the use of an extension cord because the

extension cord may overheat and cause a risk of fire.
However, if you have to use an extension cord, the
cord shall be No. 16 AWG minimum size and rated not
less than 2500 Watts.  The extension cord must be a
three wire cord with grounding type plug and cord
connection.

19. This appliance must  not be located immediately below

a socket-outlet.

20.

SAVE THESE INSTRUCTIONS.

GENERAL

1 . Read all instructions before using this appliance.

2. This appliance is hot when in use.  To avoid burns, do

not let bare skin touch hot surfaces.  If provided, use
handles when moving this appliance.  Keep combus-
tible materials, such as furniture, pillows, bedding,
papers, clothes and curtains at least 3 feet (1m) from
the front of this appliance.

3. CAUTION: Extreme caution is necessary when any

heater is used by or near children or invalids and
whenever the heater is left operating and unat-
tended.

4. If possible, always unplug this appliance when not in

use.

5. Do not operate any heater with a damaged cord or plug

or after the appliance malfunctions, or if it has been
dropped or damaged in any manner.

6. Any repairs to this fireplace should be carried out by a

qualified service person.

7. Under no circumstances should this fireplace be modi-

fied.  Parts having to be removed for servicing must be
replaced prior to operating this fireplace again.

8. Do not use outdoors.

9. This heater is not intended for use in bathrooms,

laundry areas and similar indoor locations.  Never
locate this appliance where it may fall into a bathtub or
other water container.

10. Do not run cord under carpeting.  Do not cover cord

with throw rugs, runners or the like.  Arrange cord away
from traffic areas and where it will not be tripped over.

11. To disconnect this appliance, turn controls to the off

position, then remove plug from outlet.

12. Connect to properly grounded outlets only.

13. This appliance, when installed must be electrically

grounded in accordance with local codes.

14. Do not insert or allow foreign objects to enter any

ventilation or exhaust opening as this may cause an
electric shock or fire, or damage the appliance.

15. To prevent a possible fire, do not block air intakes or

exhaust in any manner.  Do not use on soft surfaces,
like a bed, where openings may become blocked.

Your new fireplace may be installed into an existing
masonry or zero clearance fireplace.  It may also be
installed using a prefabricated cabinet available from
your dealer or be built into a wall.

When choosing a location for your new fireplace, ensure
that the general instructions are followed.  Also, for best
effect install the fireplace out of direct sunlight.

Summary of Contents for DEF33CE

Page 1: ...K OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE Installation Instructions Homeowner s Manual FOR YOUR SAFETY 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 www vermontcastings com www majesticproducts com The Vermont Castings Majestic Products Company DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE...

Page 2: ...eneral Information 3 Locating your Fireplace 3 Fireplace Dimensions 4 Electrical Specifications 4 Mantels 5 Clearance to Combustibles 5 Framing Finishing 5 Final Finishing 5 Hearth 5 Cabinet Installation 6 Electrical Connection 6 Installation of Logs 6 Service Instructions 7 Louvre Removal 7 Glass Frame Removal 7 Glass Information 7 Replacing Light Bulbs 7 Maintenance of Motors 8 Cleaning Brass Tr...

Page 3: ...e when not in use 5 Do not operate any heater with a damaged cord or plug or after the appliance malfunctions or if it has been dropped or damaged in any manner 6 Any repairs to this fireplace should be carried out by a qualified service person 7 Under no circumstances should this fireplace be modi fied Parts having to be removed for servicing must be replaced prior to operating this fireplace aga...

Page 4: ... ELECTRICAL SPECIFICATIONS Voltage 240VAC 50Hz Total Amps 9 5 Amps Total Watts 2250 Watts Heater Rating 2000 Watts 2 WHITE 1 BLACK 4 WHITE 3 BLACK 6 WHITE 5 BLACK 11 YELLOW 8 RED 5 BLACK 6 WHITE 13 BLACK 8 10 11 11 9 9 8 8 2 12 11 3 4 5 6 7 12 11 13 14 MOTOR DRUM 11 YELLOW 9 RED 8 WHITE SPEED CONTROL THERMO STAT MOTOR FAN HEATER ELEMENT DIMMER POTENIOMETER RED 10 BLACK BLACK 7 BLACK 14 WHITE 8 WHI...

Page 5: ...Ref Mantel From Mantel Leg from Depth Top Louvre Fireplace Side Maximum Minimum Minimum V 10 254 mm A 12 305 mm 10 254mm W 8 203 mm B 10 254 mm 8 203mm X 6 152 mm C 8 203 mm 6 152mm Y 4 101 mm D 6 152 mm 4 101mm Z 2 51 mm E 4 101 mm 2 51mm X Y Z WALL TOP LOUVRE OPENING E D C B A W V SIDE VIEW OPTIONAL HEARTH FRONT GLASS Fig 2 Non combustible materials such as brick and tile can be extended over th...

Page 6: ... a 7 ft 2134 mm long three wire cord exiting the right side of the fireplace Plan the installation to avoid the use of an extension cord If an extension cord must be used it must be a minimum 16AWG three wire with grounding type plug and connector and rated not less than 2500 Watts A new electrical outlet can be installed inside the frame construciton if permitted by local codes Do not use this fi...

Page 7: ...ervice person REPLACING LIGHT BULBS This fireplace uses four clear 240 Volt 50 Hz 60 Watts E 14 socket base light bulbs chandelier candle type Three of the lights are located under the ember bed of the unit The fourth light is found at the top of the firebox above the log set For convenience if one of the bulbs burns out it may be a good idea to replace all of the light bulbs Do not exceed 60 Watt...

Page 8: ... of this unit should be carried out by a licensed electrician in accordance with national and local codes If repairing or replacing any electrical component or wiring the original wire routing colour coding and securing locations must be followed Wiring Colour Code WH White BL Black RE Red CFM Majectic Factory Wire Req d 2 Motor Variable Speed 12V DC 3 potentiometer 4 Speed Control 5 Dimmer Switch...

Page 9: ...erclockwise will turn the heater function off The Heat Hi Lo Switch is located beside the On Off switch When the Heat Hi Lo Switch indicates the Off position the heat is on Low single state heat When the Heat Hi Lo Switch indicates the On position the Heat is on High full state heat 3 LOG ILLUMINATION CONTROL This control varies the brightness of the light located above the log set Turn the knob t...

Page 10: ... 10 REPLACEMENT PARTS ELECTRIC FIREPLACE ...

Page 11: ...d Control 10001168 9 Circuit Board Flame Speed Control 10002983 10 Knob Flame Speed Heater Controls Potentiometer 10001639 11 Top Louvre Assembly 10000292 12 Bottom Louvre Assembly 10000293 13 Hinge Access Door 52356 14 Trim Frame Window PB w 2 magnets 55005 15 Light Filter Ember Bed Not Shown 10001259 16 Light Diffuser Screen Not Shown 10001157 17 Screen Tinted Plastic Not Shown 10001263 18 Glass...

Page 12: ...Trim Kit Polished Brass DV33BTKP Fitting instructions included in kit Ceramic Refractory Kit DEF33CR see below for fitting instructions CERAMIC REFRACTORY INSTALLATION 1 Remove glass door assembly 2 Slide refractory panels on either side of the firebox between firebox side and the upper lintel baffle 3 Push panels against firebox side If desired secure the panels to the sides of the firebox with s...

Reviews: