4
Defiant Woodburning Stove
30003841
Specifications
Defiant, Model 1945CE
Nominal heat output .............12.6 kW (43,000 BTU/hr)
1
Minimum flue draught ......................12 Pa (0.048” WG)
Mean flue gas temp ..............................330° C (625° F)
Efficiency (space heating) ...................................76.7%
Area heated .................. Up to 223 sq. m (2,400 sq. ft.)
1
Fuel size/type ................ 559 - 610 mm (22 - 24”) wood
Flue mass gas flow ............................................. 9.6 g/s
CO Emissions (@ 13%O
2
) ............................ 1800 ppm
Loading .....................................................Front and top
Chimney Connector:
for 203 mm (8”) flue collar .... 203 mm (8”) diameter
Chimney Flue Size:
with 203 mm (8”) chimney connector
.............................................203 mm (8”) minimum
with 152 mm (6”) chimney connector
.............................................152 mm (6”) minimum
Fig. 1
Defiant dimensions.
Drawing Not to Scale
D E F I A N T
826 mm (32
���
")
724 mm
(28
���
")
788 mm (31")
96 mm
(3
���
")
546 mm (21
���
")
489 mm (19
���
")
464 mm
(18
���
")
546 mm
(21
���
")
3841
Defiant EU dimensions
7/06
768 mm
(30
���
")
D E F I A N T
591 mm (23
���
")
489 mm (19
���
")
654 mm
(25
���
")
CL
737 mm
(29")
Flue exit position ....................... Reversible, top or rear
Primary Air ... Manually set, thermostatically maintained
Secondary Air .........................................Self-regulating
Ash handling system ..................... Removable ash pan
Glass panels ........................ High-temperature ceramic
Weight ................................................ 220 kg (480 lbs.)
Width (leg to leg) ..................................... 826 mm (33”)
Depth (leg to leg) .................................. 362 mm (19
¹⁄₂
”)
Height to top of flue collar ..................... 775 mm (30
¹⁄₂
”)
1. This value can vary depending on how the stove
is operated, the type and moisture content of the fuel
used, as well as the design, construction and climatic
location of your home. Figures shown are based on
nominal fuel consumption obtained under laboratory
conditions and on average efficiencies.