14
Encore
®
FlexBurn
®
2040 Non-Catalytic / Catalytic Wood Burning Stove
30005295
Distance from the Center of the Flue Collar to the Wall in Top-Exit Installations
The information on this page is helpful in planning stove placement for top-exiting installations, particularly those in-
stallations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances
must adhere to the guidelines stated in the clearance chart on Page 13.
Dimensions indicated are valid for installations with either 6" or 8" flue collars.
Encore
®
: WITH Chimney Connector Heat Shields
Unprotected Surfaces
Protected Surfaces
Corner
Corner
Parallel Installations
Installations**
Parallel Installations
Installations**
Side (A)
Rear (B)
Corner (C)
Side (D)
Rear (E)
Corner (F)
32
1
⁄
2
" 13
1
⁄
4
" 22
1
⁄
2
" 19
1
⁄
2
" 9
1
⁄
4
" 18
1
⁄
2
"
(826 mm)
(337 mm)
(572 mm)
(495 mm)
(235 mm)
(470 mm)
**To locate center of flue collar for corner installation, add 6
1
⁄
2
" (165 mm) to the clearance distance from stove corner to wall.
Mark off the resulting distance from the corner along both walls. Next, measure the same distance from these two points out
from the walls. These last two measurements will meet at a point representing the center of the flue collar. Refer to the dia-
grams above.
ST632a
ST632a
Encore
flue centerline
Diagrams
02/01
A
B
C
D
E
F
Encore
®
: WITHOUT Chimney Connector Heat Shields
Unprotected Surfaces
Protected Surfaces
Corner
Corner
Parallel Installations
Installations**
Parallel Installations
Installations**
Side (A)
Rear (B)
Side (A)
Side (D)
Rear (E)
Corner (F)
32
1
⁄
2
" 23
1
⁄
4
" 22
1
⁄
2
" 18
1
⁄
2
" 10
1
⁄
4
" 18
1
⁄
2
"
(826 mm)
(591 mm)
(572 mm)
(470 mm)
(260 mm)
(470 mm)
* This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page:
35
1
⁄
4
" in the United States and 37
1
⁄
4
" (946 mm) in Canada.
ST632
ST632
Encore
flue centerline
Diagrams
2/01
*
A
B
C
*
D
E
F