background image

5

Vermont Castings GPF

Enclosures for LP Gas Supply Systems

If you build an enclosure for an LP gas cylinder, follow
these recommended specifications. You must also
follow local codes.

Enclosures for LP gas supply cylinders shall be
ventilated by openings at the level of the cylinder valve
and at floor level. The effectiveness of the opening(s)
for purposes of ventilation shall be determined with the
LP gas supply cylinder(s) in place. This shall be
accomplished by one of the following:

1. One side of the enclosure shall be completely open;

or

2. For an enclosure having four sides, a top and

bottom:

a. At least two ventilation openings at cylinder valve

level shall be provided in the side wall, equally sized,
spaced at 180 degrees (3.14 rad), and unobstructed.
Each opening shall have a total free area of not less
than 1/2 square inch per pound (3.2 sq. cm/kg) of
stored fuel capacity and not less than a total free
area of 10 square inches (64.5sq. cm).

b. Ventilation opening(s) shall be provided at floor level

and shall have a total free area of not less than 1/2
inch per pound (3.2 sq. cm/kg) of stored fuel
capacity and not less than a total free area of 10
square inches (64.5 sq. cm). If ventilation openings
at floor level are in a side wall, there shall be at least
two openings. The bottom of the openings shall be
at floor level and the upper edge no more than 5
inches (127mm) above the floor. The openings shall
be equally sized, spaced at 180 degrees (3.14 rad)
and unobstructed.

c. Every opening shall have minimum dimensions so

as to permit the entrance of a 1/8 inch (3.2mm)
diameter rod.

3. Cylinder valves shall be readily accessible for hand

operation. A door on the enclosure to gain access to
the cylinder valves is acceptable, provided it is
nonlocking and can be opened without the use of
tools.

4. There shall be a minimum clearance of 2 inches

(50.8 mm) between the lower surface of the floor of
the LP gas supply cylinder enclosure and the
ground.

5. The design of the enclosure shall be such that (1)

the LP gas supply cylinder(s) can be connected,
disconnected and the connections inspected and
tested outside the cylinder enclosure; and (2) those
connections which could be disturbed when
installing the cylinder(s) in the enclosure can be leak
tested inside the enclosure.

6. Be certain to mount or set the LP gas cylinder on a

flat stable surface and restrain it to prevent it from
tipping.

Purge the gas supply line of any trapped air prior to the
first firing of the unit.

WARNING: During the initial purging and
subsequent lightings, NEVER allow gas valve to
remain in the “Open” position without first placing
a burning match on the top of the burner.

Place the logs on the burner assembly. Refer to log
placement instructions.

Test fire the unit after referring to the SAFETY
INFORMATION and Lighting Instructions found on page
9.

CAUTION: Do not leave the burner on with the
cover on.

NOTE: Carbon (soot) may build up on the surface of
the logs with heavy use. This is more likely to occur
when using LP gas. The soot should be cleaned off the
surface of the logs periodically to prevent excessive
build up. To clean the logs, be sure the fire is out, the
gas supply  is turned off and the logs are cool to the
touch. The soot can then be brushed off with a dry
bristle brush or cloth. Take care while cleaning the logs
as they can become damaged if mishandled. Care
should be taken to dispose of the soot and cleaning
materials properly. Keep away from clothing and
outdoor furniture.

Summary of Contents for GPFMN

Page 1: ...s or any other appliance FOR YOUR SAFETY If you smell gas Do not touch any electrical switches Do not try to light any appliance Extinguish any open flame Do not use the phone in your build ing Immedi...

Page 2: ...allation 4 Log Placement 7 Operation 9 Maintenance 10 Replacement Parts 11 Accessories 12 11 292mm 5 127mm 12 305mm 3 83mm 16 413mm 11 289mm 8 210mm Burner GPF Dimensions 4237 Fig 1 Physical dimension...

Page 3: ...area clear and free from combustible materials gasoline and other flammable vapors and liquids Do not locate appliance where it can get excessively wet Do not use this appliance if any part has been u...

Page 4: ...proper external mating threads Tank valve Marked USE WITH TYPE 1 5 Inspect hose shipped with the unit for damage Never attempt to use damaged or plugged equipment See your local LP Gas Dealer for rep...

Page 5: ...and operation A door on the enclosure to gain access to the cylinder valves is acceptable provided it is nonlocking and can be opened without the use of tools 4 There shall be a minimum clearance of 2...

Page 6: ...7 16 3 4 and 11 16 wrenches phillips screwdriver Installation Instructions 1 Remove octagonal plate from shipping carton 2 Remove base Villa from shipping carton Remove four 4 1 4 20 fasteners four 4...

Page 7: ...ly through the fuel line opening in the base Place the octagonal mounting plate on the Chalet Fig 8 Orient the plate with the long side of the rectangular opening parallel to the valve panel Pass the...

Page 8: ...over on or removing the cover from the unit to avoid damaging the logs CAUTION Log C4 Log C5 Log C1 Log C2 LG165a Fig 14 Log C5 placement Log C5 Log C1 Log C6 Log C4 Log C2 Log C3 LG166a Fig 15 Log C6...

Page 9: ...re to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not us...

Page 10: ...the hose connecting the LP gas cylinder to ensure it is not damaged in any way High Elevation Installation This U L listed gas appliance is tested and approved for elevations form 0 to 2 000 feet in...

Page 11: ...tural Supply Line 50000198 7a Short Stem Orifice Natural 20004497 7b Short Stem Orifice LP 20004498 8 Volcanic Rock 20000198 9 LP Gas Cylinder Base 20004578 10 LP Conversion Kit 20004752 11 NG Convers...

Page 12: ...el Number Patio Fire Optional Safety Screen Kit PFOSK Villa Patio Fire Urn Base PFCBUMB Chalet Patio Fire Octagonal Base PFCBOMB CAUTION This appliance is a highly engineered system and as such must b...

Page 13: ...mont Castings Majestic Products Company sont garanties pour la vie de l acheteur d origine le tout sujet une preuve d achat et aux conditions et limitations suivantes 1 Ce nouveau produit Vermont Cast...

Page 14: ...ngs GPF 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com The Vermont Castings Majestic Products Company The Vermont Castings Majestic P...

Reviews: