73D0024
33
KHLDV Series Gas Fireplace
SIGnature coMManD - optIonaL Fan BLower SySteM
To Junction Box
In Fireplace
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
Connector
Pin To Contro l Box
{
{
Light
Optional
AUX
FP2684
BLOTKHLSC fan wiring
Blower (300w Max)
Figure 41 -
BLOTKHLSC Blower Wiring Diagram
FP2705
control Box
note
the black and white wires on the ac box
wiring harness are marked ‘Blower’, ‘Light’
and ‘aux’. It is important to use the wires
marked ‘Blower’ or the control will not work
correctly.
w
arn
In
G
electrical connections should only be
performed by a qualified licensed electrician.
Main power supply must be turned off before
connecting the fan to the main electrical
power supply or performing service.
BLotKHLSc SIGnature coMManD BLower
electrical Grounding Instructions: this
appliance is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle.
w
arn
In
G
The BLOTKHLSC Blower Kit requires the SCSACM A/C
Module and the TSFRSC remote to install and operate
this kit. Refer to blower instructions for installation and
remote instructions for operation.
ac Module