8
20306748
MLDV Series Gas Fireplace
CLEARANCES
CLEARANCES TO COMBUSTIBLES
71” Minimum
Ceiling
12” Max.
Depth
14” Min.
From Opening
6” Min.
to Opening
Figure 4 -
Side Wall and Ceiling Clearances
Side Wall
Combustible
Mantel
Figure 5 -
Mantel clearances.
6"
5"
3"
2
56O
"
4
56O
"
45°
3
56O
"
1"
1
56O
"
Fireplace
Opening
Wall
Combustible
Material Area
Top View
Follow these instructions carefully to
ensure safe installation. Failure to follow
in struc tions exactly can create a
fi
re hazard.
The appliance cannot be installed on a
carpet, tile or other combustible material
other than wood
fl
ooring. If installed on
carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or
noncombustible material panel ex tend ing
full width and depth of the appliance.
W
ARNING
NOTE:
When eyebrow canopy is used, minimum clearance to combustibles is 2
1
⁄
4
" maximum out from
fi
replace front at
7
1
⁄
2
" minimum from opening.
Figure 5a.
When eyebrow is not used, clearances to combustibles is 8" maximum out from
fi
replace front at 10" minimum from opening or 12" maximum out from
fi
replace front at 14" minimum from opening.
Figure 5
8” Max.
10”
Min.
7
56O
”
Min.
1
56O
”
Max.
2
56M
” Max.
14”
Min.
12” Max.
3/4"
Marble
Combustible
Breastplate
Figure 5a -
Mantel Clearance with Eyebrow Canopy
Eyebrow
Canopy