background image

15

20004180

NESS FOR A PARTICULAR PURPOSE), ALL OF WHICH 
ARE HEREBY EXPRESSLY INCLUDED. IN NO EVENT 
SHALL ANY IMPLIED WARRANTY PRESCRIBED BY LAW 
(NOTWITHSTANDING THE FOREGOING EXPRESS EX-
CLUSION) REMAIN IN EFFECT AFTER EXPIRATIONS OF 
THE WARRANTIES SET FORTH IN PARAGRAPHS A AND 
B.

    A. Gas Appliances, electrical and manual compo-
nents, glass panels, all sealants or adhesives and 
optional accessories 

(exclusive of CFM Specialty Home 

Products supplied decorative logs which are covered by a 
separate warranty under paragraph B below):
    Within two years from the date of manufacture of the 
gas appliance, CFM Specialty Home Products will repair, or 
replace (at our option) a defective part without charge.

   B.  Cement or ceramic fiber log components:

Within two years from the date of manufacture of the gas 
appliance, CFM Specialty Home Products will replace a 
defective part without charge.  Within years three through 
twenty from the date of manufacture of the gas appliance, 
CFM Specialty Home Products will provide a replacement 
for a defective part to the homeowner, but assumes no li-
ability for incurred labor cost.
    The foregoing  warranties gives you specific legal rights 
and you may also have other rights which vary from state to 
state.  Some states do not allow limitations on how long an 
implied warranty may last, so the limitation specified above 
on the duration of any implied warranty prescribed by law 
may not apply to you.  Similarly, some states do not permit 
the exclusion or limitation of incidental or consequential 
damages, so the above exclusion of such damages may not 
apply to you.
    In order to obtain performance of any of the above war-
ranty obligations, write to CFM Specialty Home Products at 
this address:
  CFM Specialty Home Products
  410 Admiral Blvd
  Mississauga, Ontario Canada L5T 2N6
  Attention: Manager of Warranty Services

   
  Since local building requirements may vary greatly 
throughout the country, users of CFM Specialty Home Prod-
ucts products should determine in advance whether there 
are any building code restrictions on the use of a specified 
product.
CFM SPECIALTY HOME PRODUCTS MAKES NO REPRE-
SENTATION OR WARRANTY REGARDING, AND SHALL 
NOT BE RESPONSIBLE FOR, ANY BUILDING CODE 
COMPLIANCE.

  The foregoing warranties give you specific legal 

rights and you may also have other rights which vary from state to state.

  CFM Specialty Home Products extends the warranties 
specified in paragraphs A and B below with respect to its 
Vermont Castings Decorative Gas Appliances (the “Gas Ap-
pliance”), including CFM Specialty Home Products supplied 
accessories and components referred to in those para-
graphs, subject to the following conditions and limitations:
    (1) These warranties are extended only to the Gas Ap-
pliance installed in the continental United States, including 
Alaska, and Canada; only if and so long as the accordance 
with the installation and operating instructions furnished 
therewith; and only if and so long as Gas Appliance is not 
removed from its original installation.
    (2). These warranties are limited to only the component 
parts manufactured and supplied by CFM Specialty Home 
Products. The use of components manufactured by others 
with the Gas Appliance (except for a listed Type B venting 
system as defined in the installation instructions) could cre-
ate serious safety hazard, may result in the denial of  certifi-
cation by recognized national safety agencies, and could be 
in violation of local building codes.
   (3). The Gas Appliance must be operated at all times in 
accordance with the operating instruction furnished there-
with. The Gas Appliance is designed to burn either natural or 
propane gas only.  Burning conventional fireplace fuels such 
as wood, coal, or any other solid fuel will cause damage to 
the Gas Appliance, will produce excessive temperatures and 
will result in a fire hazard.
    (4). These warranties are limited to repair, replacement or 
furnishing a replacement for sale, as specified in Paragraphs 
A and B, for a part found to CFM Specialty Home Products 
satisfaction, after examination, to be defective in materials or 
workmanship under normal conditions, use and service.
    (5).  All obligations with respect to these warranties may 
be fully discharged by CFM Specialty Home Products re-
funding the wholesale price of a defective part.
    (6)  Except as otherwise expressly specified in Para-
graphs A and B. NONE OF THESE WARRANTIES COVER, 
AND CFM SPECIALTY HOME PRODUCTS SHALL NOT 
BE RESPONSIBLE FOR, ANY CONSTRUCTION, INSTAL-
LATION, LABOR, TRANSPORTATION OR OTHER COSTS 
OR EXPENSES ARISING FROM A DEFECTIVE PART, 
ITS REPAIR OR REPLACEMENT OR OTHERWISE, NOR 
SHALL CFM SPECIALTY HOME PRODUCTS IN ANY 
EVENT BE RESPONSIBLE FOR ANY INDIRECT, INCIDEN-
TAL OR CONSEQUENTIAL DAMAGES.  EXCEPT TO THE 
EXTENT PROVIDED BY LAW, THERE ARE NO IMPLIED 
WARRANTIES WITH RESPECT TO THE GAS APPLIANCE, 
ITS COMPONENTS AND ACCESSORIES (INCLUDING 
IMPLIED WARRANTIES OF MERCHANTABILITY OR FIT-

LIMITED 2/20 YEAR WARRANTY

For VERMONT CASTINGS Decorative Gas Appliances

Summary of Contents for OD30CFLN/P

Page 1: ... COMPANY EXPE RIENCED IN THE INSTALLATION REPAIR AND SERVICING OF THIS TYPE OF GAS APPLIANCE DO NOT MODIFY ALTER OR TAMPER WITH ANY PART OF THIS HEATER CONTROL OR LOGS INSTALLER PLEASE NOTE DO NOT BEGIN INSTALLATION OF THIS GAS LOGSET UNTIL ALL INSTRUCTIONS HAVE BEEN READ AND UNDERSTOOD Certified as CSA 7 94 U S manually lighted decorative gas appliance for installation in solid fuel burning firepla...

Page 2: ... air are provided the screen shall have an opening s for introduction of combustion air The log set and its individual shut off valve MUST be isolated from the gas supply piping system by closing its individual shut off valve during any pressure testing of gas supply at test pressures equal to or less than 1 2 psig The log set and its individual shut off valve MUST be disconnected from the gas sup...

Page 3: ...ct you in the event of an explosion WARNING If the fireplace contains glass doors they must remain open at all times during the opera tion of the logset allowing combustion air to circulate In order to avoid any possible gas leaks apply pipe joint compound to all non flared threaded connections involved in this installation For propane the joint compound must be resistant to the corrosive action of ...

Page 4: ... Supply Set Input Width Flue Pressure Size Btu hr Back Front Depth Height Size Minimum Maximum 30 90 000 27 36 18 18 79 sq in 3 5 w c 7 0 w c Minimum Clearances Specifications Natural Gas Units Propane Gas Units Gas Log Minimum Firebox Dimensions Minimum Gas Supply Set Input Width Flue Pressure Size Btu hr Back Front Depth Height Size Minimum Maximum 30 60 000 27 36 18 18 79 sq in 11 0 w c 14 0 w c...

Page 5: ...or burner connection purposes only Ex act burner placement will be covered on Page 7 after all connections have been made 3 Attach the Gas Supply Fitting onto your fireplace s gas supply pipe as shown in Figure 2 4 Attach one end of the Flexible Gas Connector to the brass Burner Inlet Fitting which has been factory installed into the burner 5 Attach the other end of the Gas Connector to the flared s...

Page 6: ...ng the bolt provided to the damper plate with an adjustable wrench Fig 5 If the Damper Stop does not fit drill a 1 4 hole into the damper plate and install an anchor bolt with nut at a 90 degree angle so that the damper plate will remain fully open The proper finished installation of the Damper Stop is shown in Figure 6 If the bolt fails to block the damper in an open position the damper should be r...

Page 7: ...y across burner covering lava rock Fig 9 3 Slide the mesh screen under the grate but on top of glowing embers so the mesh piece covers the burner pan material Fig 10 4 Open remaining bag of embers and place evenly on top of mesh screen Fig 10 5 Spread lava rock onto fireplace hearth around the burner pan for decorative purposes Fig 11 FP1146 OD30 embers 8 13 01 djt Glowing Embers FP1146 Fig 9 Ember...

Page 8: ...one side of the cover on the front edge of the hearth brick just behind the ash lip Fig 14 inside the screens Allow the back edge of the cover to rest against the back and side brick covering the log set 2 Place the second half of the cover in the same manner overlapping the first half Fig 15 CAUTION Be sure to remove cover before lighting gas log set KT260 ODLSSC side view KT260 Fig 14 ODLSSC inst...

Page 9: ...in which the log set is installed Appliance Break in During the 2 3 hour appliance break in period you may detect an odor from the appliance as the various water based paints used in the manufacture of this log set cure This is a normal and temporary situation that is not a cause for alarm To ensure proper curing of the logs 1 Ignite a 2 flame and maintain it for 1 2 hour 2 Burn the logs in consecu...

Page 10: ...nstalled the correct orifice into the set Burner Is Excessively Noisy Please note The movement and combustion of gas will create low unavoidable levels of noise Excessive gas pressure Make sure the gas pressure coming into the fireplace does not exceed the maximum pressure allowed with this gas set refer to tables on page 4 If you are using the gas logs with a safety pilot kit make sure you installe...

Page 11: ...1c Center Left Cross Log NEO 2 4312847 1d Center Right Cross Log NNO 3 4312848 1e Outside Right Cross Log NNS 3 4312779 1f Back Log NNS30B 4312814 1g Front Left Log KO 30L 4312857 1h Front Right Log KO 24L 4312844 2 Bag of Glowing Embers 4310001 3 Bag of Lava Rock 3310041 4 Grate Step 20004202 5 Damper Stop 20002575 6 Burner Tube 3 8 20003828 7 Pan Assembly 20004179 8 Orifice Natural Gas 20000961 9...

Page 12: ... Regulator Propane 3304191 16 Orifice Propane 20001280 17 Orifice Holder Propane 20000012 18 Air Mixer Shutter 20000013 19 Air Shutter Screen 20004686 Optional Accessories Item Description Part Number Grate Stainless Steel For use in fireplaces other than the ODSHR42 20002230 ...

Page 13: ...13 20004180 ...

Page 14: ...14 20004180 ...

Page 15: ...nties specified in paragraphs A and B below with respect to its Vermont Castings Decorative Gas Appliances the Gas Ap pliance including CFM Specialty Home Products supplied accessories and components referred to in those para graphs subject to the following conditions and limitations 1 These warranties are extended only to the Gas Ap pliance installed in the continental United States including Alas...

Page 16: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products ...

Reviews: