20300293
5
Resolution Direct Vent Gas Fireplace
pRODuct FeatuRes
•
This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
FP2594
VHLDV controls
Command Center
Figure 1 -
VHLDV Fireplace Controls
Gas Valve
Control Box
Access Panel
FP2594
Gas pRessuRes
HIGH eLeVatIOns
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
Gas specIFIcatIOns & ORIFIce sIZe
Orifice size
Model
Fuel
Front
Rear
VHLDV500 Nat.
2.3 mm
#30 (.1285)
VHLDV500 LP
#50 (.070")
#55 (.052")
Btu/hr Input
Max.
Min.
Min. Front
Model
Fuel
all
all
Burners
Burners Burners
Only
VHLDV500NTSC Nat. 50,000
35,500
17,500
VHLDV500PTSC
LP
50,000
38,500
17,500