INSTALLER:  DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

 10000834

11/01  Rev. 2

DO NOT STORE

OR USE GASOLINE OR OTHER

FLAMMABLE VAPOURS AND LIQUIDS

IN THE VICINITY OF THIS OR ANY

OTHER APPLIANCE.

FOR YOUR SAFETY

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch

Do not use any phone in your building.

Immediately call your gas supplier from
your neighbours phone. Follow the gas
suppliers instructions.

If you cannot reach your gas supplier call
the fire department.

WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR

EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

Installation and service must be performed by a
qualified installer, Service agency or your gas
supplier.

Free-Standing

Fireplaces

RFS22
RFS32
RFS42

Installation Instructions & Homeowner's Manual

410 Admiral Blvd., Mississauga

Ontario, Canada  L5T 2N1

www.majesticproducts.com / www.vermontcastings.com

The Vermont Castings

Majestic Products Company

Summary of Contents for RFS22

Page 1: ...llow the gas suppliers instructions If you cannot reach your gas supplier call the fire department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Installation and service must be performed by a qualified installer Service agency or your gas supplier Free Standing Fireplaces RFS...

Page 2: ...n 5 Gas Line Installation 5 Installation of Remote Switch for RN RP gas valve 6 Fan Kit 6 General Venting Information 7 Common Flue Installation 7 Retrofitting to an Existing Brick Chimney 8 Vent Safety System 8 Proper Vent Performance 8 Combustion Air 8 Operating Instructions 9 General Glass Information 9 Louvre Removal 9 Trim Removal 9 Glass Removal 9 Glass Cleaning 10 Installation of Logs and B...

Page 3: ...ck for clothing nor should Christmas stock ings or decorations be hung in the area of it 9 Undernocircumstancesshouldanysolidfuels wood coal paper or cardboard etc be used in this fire place 10 The flow of combustion and ventilation air must not be obstructed in any way 11 When the fireplace is installed directly on carpeting vinyltileoranycombustiblematerialotherthanwood the fireplace must be ins...

Page 4: ...29 5 8 752mm J 9 229mm K 5 1 4 133mm L M N MODEL RFS32 A 26 660mm B 26 660mm C 15 1 4 387mm D 19 1 4 488mm E 18 5 8 473mm F 21 533mm G 31 1 2 800mm H 17 3 4 451mm I 29 5 8 752mm J 95 8 244mm K 5 1 4 133mm L M N MODEL RFS22 A 28 1 4 717mm B 28 1 4 717mm C 17 7 8 454mm D 22 3 4 578mm E F G H 22 3 4 578mm I 33 5 8 854mm J 10 5 8 270mm K 5 1 4 133mm L 36 3 8 924mm M 14 3 16 360mm N 17 3 8 441mm MODEL ...

Page 5: ...ting the gas line The gas line connection can be made with properly tinned 3 8 copper tubing 3 8 rigid pipe or an approved flex connector Since some municipalities have some additional local codes it is always best to consult your local authority and the CAN CGA B149 1 or 2 installation code PREPARATION The use of wall paper adjacent to this fire place is not recommended as the high heat given off...

Page 6: ...d Fig 7 3 Locate the fan speed control junction box on screw studs provided on base of the fireplace Tighten with 3 8 nuts provided 4 Install thermal sensor element on screw studs located to the right of the gas valve on the burner base 5 Plug in grounded service cord to a convenient wall receptacle THIS FAN ASSEMBLY COMES COMPLETELY WIRED TO ELIMINATE THE NEED FOR ELECTRICIANS THIS ELECTRICAL DEV...

Page 7: ...ng the full height of the chimney as it is mandatory in most jurisdictions that the chimney be lined Another option is 4 B vent directly off the fireplace Fig 9 11 going up to the chimney liner or up through the roof if no chimney exists VENTING INSTRUCTIONS CANADIAN INSTALLATIONS The venting system must be installed in accordance with the current CAN CGA B149 1 or 2 installation code and the auth...

Page 8: ...g blown back into room the Vent Safety Switch will automatically shut down the heater 4 Should the heater turn off wait approximately 10 15 minutes to allow for the switch to reset Check draft again If the smoke is not drawn into the draft hood turn the fireplace off and check the cause of lack of draft consult your dealer for expert advice VENT SAFETY SYSTEM This fireplace is equipped with a vent...

Page 9: ...REMOVAL RFS22 1 Remove frame window brass trim See Trim Removal section 2 Remove remaining bottom 3 8 nut at the bottom of the frame window 3 Remove frame window by pulling it forward and up RFS32 1 Remove frame window brass trim See Trim Removal section 2 Remove remaining bottom 3 8 nut fat the bottom of the frame window 3 Remove 3 8 nut from each side of the frame window Fig 14 4 Remove frame wi...

Page 10: ...hes Ensure log is secure Top logs must be placed properly into notches RFS42 1 Remove Bay Window assembly and Glass Frame see Glass Frame Removal section 2 Remove logs from packaging 3 Place rear log SR4 on rear bracket Ensure log is seated properly leveled and centered to the unit so it will not move from side to side and it is firmly positioned on the bracket 4 Slip front ember log SR1 down in t...

Page 11: ...back of the firebox 5 Take left or right side refractory and slide it along the side of the firebox and on top of the bottom support channel Be sure to slide it back to hold the centre piece in place and the leading edge faces forward 6 Fasten top tab support against the refractory to hold it in place 7 Repeat steps 5 and 6 for remaining side refactory 8 Insert refractory pieces into the Bay Windo...

Page 12: ...ass FrameRemovalinmanual 8 Visiblylocatepilotbythemainburner 9 Turnknobongascontrolcounterclockwise to PILOT C Useonlyyourhandtopushinorturnthegascontrol knob Neverusetools Iftheknobwillnotpushinorturn byhand donottrytorepairit callaqualifiedservice technician Applyingforceoranyattemptedrepairmay resultinafireorexplosion D Donotusethisfireplaceifanyparthasbeenunderwater Immediatelycallaqualifiedse...

Page 13: ...efective automatic valve Turn valve knob to Pilot Maintain flow to pilot millivolt operator meter should read greater than 10 mV If the reading is okay and the pilot does not stay on replace the gas valve Note An interrupter block not supplied must be used to conduct this test 3 Pilot burning no gas to A Sensing bulb not in proper Make sure sensing bulb is located in bracket on the lower burner Va...

Page 14: ...ct this test 3 Pilot burning no gas to A Wall switch or wires Check wall switch and wires for proper connections Jumper burner Valve knob ON defective wire across terminals at wall switch if burner comes on Wall Switch ON replace defective wall switch If okay jumper wires across wall switch wires at valve if burner comes on wires are faulty or connections are bad B Thermopile may not be 1 Be sure ...

Page 15: ... ADJUST PILOT FLAME HEIGHT ALL WIRING CONNECTIONS REPLACE THERMOPILE THERMOCOUPLE NEEDS A MINIMUM OF 14mV DEFECTIVE VALVE TURN TO PILOT METER SHOULD READ GREATER THAN 100 mV IF NOT REPLACE PILOT LIGHTS WITH PIEZO IGNITOR YES YES YES YES PILOT STAYS LIT PILOT LIGHTS MAIN BURNER SYSTEM OK START CHECK VALVE IS TURNED ON ON OFF SWITCH IS NOT TURNED ON WATCH FOR GROUNDED WIRES THERMOPILE NEEDS A MINIMU...

Page 16: ...17 Thermopile 53374 53374 53374 18 Electrode Ignitor w cable SIT 52465 52465 52465 19 Ignitor Piezo SIT 52464 52464 50932 20 Ignitor Piezo Honeywell 2000062 2000062 2000062 21a Valve SIT 820 Nat 52677 52677 52677 21b Valve SIT 820 Prop 52678 52678 52678 22 Extension Knob Hi Lo RN RP 10000165 10000165 55162 23 Extension Knob On Off SIT RN RP 10000166 10000166 55163 24a Valve Honeywell Nat 10001782 ...

Page 17: ...2 36 a b 37 39 46 45 39 43 41 42 it H I L O O F F P IL O T 25a b 48 47 40 14 33 38 42 39 34 35 39 43 33 49 26 1 COMPLETE LOG SET RFS22 RFS32 1b 1d 1e 1f 1a 1c 22 23 3a b 4 2 40 8 a b 12 17 16 L O H I PILOT ADJ P I L O T ON OFF 24 a b 20 10 a b 9 a b 1COMPLETELOGSETRFS42 1d 1f 1e 1c 1b 1a ...

Page 18: ... On Off Button Remote Control MRC2 Temperature Control Remote MRC3 Temperature Control w digital display 24 hour programmable clock IMT Wall Mounted Thermostat REMOTE CONTROL For units with RN RP valves OPTIONS ...

Reviews: