7
RFSDV34 Freestanding Direct Vent Gas Stove
10003550
CFM106
Typical Gas Line Connection
9-29-00
1/” Gas Supply
1/” x 3/8” Reducer
3/8” Nipple
3/8” x 3/8”
Shut-Off Valve
3/8” Nipple
3/8” Union
3/8” Nipple
CFM106
Fig. 3
Typical gas line connection.
Installation of Remote Switch
for RSN/RSP Gas Valve
NOTES: The remote ON/OFF switch cannot be fitted
to units using the Honeywell Radio Frequency con-
trol valve.
If the stove has been fitted with the RCSITEA Con-
trol, the ON/OFF function is controlled by the remote
handset or receiver switch. Refer to Page 22.
Install the ON/OFF switch assembly on either the rear
right or rear left side of the stove.
1. Remove the screw at the back of the cabinet top either
on the left or the right side of the stove.
. Position switch assembly onto the back of the stove,
then fasten two () screws as shown in Figure 3.
3. Attach wiring under the clips on the rear casing (Fig. 4)
and install wiring through the rear opening of the stove
before connecting to the valve as shown in Figure 5.
&02&3$6SWITCH
ON/OFF Switch
Assembly
Clips
Screw
Screw
(through existing
hole)
Wiring for
Millivolt Gas
Valves
FP161
Fig. 4
Attach wiring under clips on rear casing.
P
ILO
T
TPTH
TP
TH
&0
3)4VALVEWSWITCH
Valve
Thermopile
FP16
ON/OFF Switch or
Millivolt Thermostat
SIT Valve
Fig. 5
Install wiring to switch before connecting to valve.