background image

THE FOREGOING EXPRESS EXCLUSION) REMAIN IN 
EFFECT AFTER EXPIRATIONS OF THE WARRANTIES 
SET FORTH IN PARAGRAPHS A AND B.

    A. Gas Appliances, electrical and manual compo-
nents, glass panels, all sealants or adhesives and op-
tional accessories 

(exclusive of CFM Corporation supplied 

decorative logs which are covered by a separate warranty 
under paragraph B below):
    Within two years from the date of manufacture of the gas 
appliance, CFM Corporation will repair, or replace (at our 
option) a defective part without charge.

   B.  Cement or ceramic fiber log components:

Within two years from the date of manufacture of the gas 
appliance, CFM Corporation will replace a defective part 
without charge.  Within years three through twenty from the 
date of manufacture of the gas appliance, CFM Corporation 
will provide a replacement for a defective part to the hom-
eowner, but assumes no liability for incurred labor cost.
    The foregoing  warranties gives you specific legal rights 
and you may also have other rights which vary from state to 
state.  Some states do not allow limitations on how long an 
implied warranty may last, so the limitation specified above 
on the duration of any implied warranty prescribed by law 
may not apply to you.  Similarly, some states do not permit 
the exclusion or limitation of incidental or consequential 
damages, so the above exclusion of such damages may not 
apply to you.
    In order to obtain performance of any of the above war-
ranty obligations, write to CFM Corporation at this address:
  CFM Corporation
  410 Admiral Blvd
  Mississauga, Ontario Canada L5T 2N6
  Attention: Manager of Warranty Services

   
  Since local building requirements may vary greatly 
throughout the country, users of CFM Corporation products 
should determine in advance whether there are any building 
code restrictions on the use of a specified product.
CFM CORPORATION MAKES NO REPRESENTATION OR 
WARRANTY REGARDING, AND SHALL NOT BE RE-
SPONSIBLE FOR, ANY BUILDING CODE COMPLIANCE.

 

The foregoing warranties give you specific legal rights and you may 
also have other rights which vary from state to state.

  CFM Corporation extends the warranties specified in 
paragraphs A and B below with respect to its Vermont 
Castings Decorative Gas Appliances (the “Gas Appliance”), 
including CFM Corporation supplied accessories and 
components referred to in those paragraphs, subject to the 
following conditions and limitations:
    (1) These warranties are extended only to the Gas Ap-
pliance installed in the continental United States, including 
Alaska, and Canada; only if and so long as the accordance 
with the installation and operating instructions furnished 
therewith; and only if and so long as Gas Appliance is not 
removed from its original installation.
    (2). These warranties are limited to only the component 
parts manufactured and supplied by CFM Corporation. The 
use of components manufactured by others with the Gas Ap-
pliance (except for a listed Type B venting system as defined 
in the installation instructions) could create serious safety 
hazard, may result in the denial of  certification by recog-
nized national safety agencies, and could be in violation of 
local building codes.
   (3). The Gas Appliance must be operated at all times in 
accordance with the operating instruction furnished there-
with. The Gas Appliance is designed to burn either natural or 
propane gas only.  Burning conventional fireplace fuels such 
as wood, coal, or any other solid fuel will cause damage to 
the Gas Appliance, will produce excessive temperatures and 
will result in a fire hazard.
    (4). These warranties are limited to repair, replacement or 
furnishing a replacement for sale, as specified in Paragraphs 
A and B, for a part found to CFM Corporation satisfaction, 
after examination, to be defective in materials or workman-
ship under normal conditions, use and service.
    (5).  All obligations with respect to these warranties may 
be fully discharged by CFM Corporation refunding the whole-
sale price of a defective part.
    (6)  Except as otherwise expressly specified in Para-
graphs A and B. NONE OF THESE WARRANTIES COVER, 
AND CFM CORPORATION SHALL NOT BE RESPON-
SIBLE FOR, ANY CONSTRUCTION, INSTALLATION, 
LABOR, TRANSPORTATION OR OTHER COSTS OR 
EXPENSES ARISING FROM A DEFECTIVE PART, ITS RE-
PAIR OR REPLACEMENT OR OTHERWISE, NOR SHALL 
CFM CORPORATION IN ANY EVENT BE RESPONSIBLE 
FOR ANY INDIRECT, INCIDENTAL OR CONSEQUEN-
TIAL DAMAGES.  EXCEPT TO THE EXTENT PROVIDED 
BY LAW, THERE ARE NO IMPLIED WARRANTIES WITH 
RESPECT TO THE GAS APPLIANCE, ITS COMPONENTS 
AND ACCESSORIES (INCLUDING IMPLIED WARRANTIES 
OF MERCHANTABILITY OR FITNESS FOR A PARTICU-
LAR PURPOSE), ALL OF WHICH ARE HEREBY EX-
PRESSLY INCLUDED. IN NO EVENT SHALL ANY IMPLIED 
WARRANTY PRESCRIBED BY LAW (NOTWITHSTANDING 

LIMITED 2/20 YEAR WARRANTY

For VERMONT CASTINGS Decorative Gas Appliances

Summary of Contents for SA18SHKRN

Page 1: ...A18SHKRP SA24SKHRN SA24SHKRP SA30SKHRN SA30SKHRP ATTENTION Installation service and repair of this ap pliance must be performed by a qualified installer service agency company or gas supplier experienced with this type of gas appliance INSTALLER Read these instructions completely and care fully prior to beginning installation After instal lation leave these instructions with the owner OWNER Read th...

Page 2: ...2 psig 3 5 kPa Component Parts Only factory authorized components listed in these instructions may be used in accordance with the manufacturer s instructions and all codes and requirements of the authority hav ing jurisdiction Any modifications to this kit or use of unauthorized components or accessory items will void the manufacturer s warranty and may result in a hazardous condition WARNING Due t...

Page 3: ...lace supply tanks inside any structure G Never use sand or other dense pan material with propane gas use vermiculite only H Be sure to apply pipe joint compound to all non flared threaded connections involved in this installa tion to avoid possible gas leaks Compounds used in liquid propane applications must be resistant to the action of that gas I Always test for leaks using a soapy solution NEVER...

Page 4: ...g codes Check with your local building department Does your fireplace have a wire mesh screen in place Pre Installation Checklist Yes No Minimum Clearances Specifications Natural Gas Units Propane Gas Units Size Btu hr Back Front Depth Height Size Minimum Maximum 18 45 000 16 33 15 18 51 sq in 5 5 w c 14 0 w c 3 5 w c 24 60 000 20 36 15 18 51 sq in 5 5 w c 14 0 w c 3 5 w c 30 60 000 27 39 15 18 51 s...

Page 5: ...end of the Damper Lock ing Bracket If this is the case use the Damper Stop as a template to drill two 2 1 8 holes in the Damper Locking Bracket to mount the Damper Stop NOTE Your gas log set is assembled at the factory to be installed in a fireplace plumbed with the gas on the right side facing If your fireplace is plumbed with the gas on the left side you will need to run a flex ible connector or as...

Page 6: ... so that the damper plate will remain fully open The proper finished installation of the Damper Clamp is shown in Figure 4 If the bolt fails to block the damper in an open position the damper should be removed from the chimney To check your vent for proper drafting Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace Observe the smoke and be sure the ven...

Page 7: ... burner pan into the three pronged slot in the front edge of the grate clip as shown in Figure 6 1 Center the burner pan from left to right in the fireplace and with the back of the grate against the back wall of the fireplace 2 Attach the Gas Supply Fitting onto your fire place s gas supply pipe Remember to use pipe thread sealant or teflon tape on this connection 3 Attach one end of the Flexible Gas...

Page 8: ...ocedure until no bubbles appear in the soap solution Remember to test all joints WARNING DO NOT USE AN OPEN FLAME TO TEST FOR LEAKS NOTE Always perform a leak test any time the appliance has been moved or disconnected from the gas supply line Remote Installation Connect remote GWSK or MRC 1 2 3 wires to ON OFF RS switch Fig 8 If the MRC remote is used the receiver can be placed to the front right ...

Page 9: ...eve your desired flame pattern Be sure you leave as much open space between the logs as possible to minimize flame impinge ment and sooting 3 Open the bag of lava rock and spread the rocks onto the fireplace floor around the burner pan for decorative purposes Available Log Sets LG330 18 Standard round log set 4 04 djt LG330 18 Standard Round Log Set 24 Standard Round Log Set LG331 LG331 24 Standard ro...

Page 10: ...dard Split Log Set LG334 LG335 30 Standard split log set 4 04 djt 30 Standard Split Log Set LG335 LG336 18 Standard combo log set 4 04 djt 18 Standard Combination Log Set LG336 LG337 24 Standard combo log set 4 04 djt 24 Standard Combination Log Set LG337 LG338 30 Standard combo log set 4 04 djt 30 Standard Combination Log Set LG338 ...

Page 11: ...tay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 8 Turn gas control knob counterclockwise to ON CAUTION Be sure ON OFF RS switch is in the off middle position Also the GWSK should be in the OFF position and or the remote should be in the OFF position before turning the control knob ON If pilot goes out repeat steps 4 and 5 9 Turn ON OFF ...

Page 12: ... on Page 4 Incorrect Orifice used Check the orifice size on Page 15 to see if you installed the correct orifice into the set Burner Is Excessively Noisy Please note The movement and combustion of gas will create low unavoidable levels of noise Passage of air gas across irregular surfaces There may be burrs paint or other blockages on the burner bar ports Check these ports and remove any blockage Exce...

Page 13: ...r customer service line Incorrect Pilot Orifice Make sure the correct Pilot Orifice is installed green for Natural Gas red for propane Incorrect gas supply pressure Make sure your gas pressure meets the specifications outlined on Page 4 Flames at the Air Mixer Flashback Propane Gas Only Correct Orifice used Check the chart on Page 15 to see if you used the correct Orifice Also be sure you only used the...

Page 14: ...20007269 3 Cast Front Grate w Clips CIGF 18 CIGF 24 CIGF 30 4 Grate Clip Fettel 3304311 3304311 3304311 5 Screw Grate Clip 3309078 3309078 3309078 6 Bag of Lava Rock 8lbs 4310010 4310010 4310010 7a Bag of Sand Natural Gas Models ONLY 4310006 4310006 4310006 7b Bag of Vermiculite 4310008 4310008 4310008 8 Bag of Glowing Embers 4310001 4310001 4310001 9 Damper Stop for CFM Corporation Fireplaces ONL...

Page 15: ...9 41 Log Set Replacement Parts Ref Description Log Sets 1 18 Standard Round Log Set 20007854 1a 24 30 Round Right Front 20007833 1b 18 Round Left Front 20007835 1c 24 30 Round Front Cross Log 20007834 1d 18 24 30 Cross Log 20007837 1e 18 Cross Log 20007836 1f Top Log 20008335 2 24 Standard Round Log Set 20007855 2a 24 30 Round Left Front 20007839 2b 24 30 Round Right Front 20007838 2c 24 30 Back L...

Page 16: ...4b 4c 4d 4e 4f 4 5 6a 6b 6c 6d 6e 2 6f 2 6 7a 7b 7c 7d 7e 7 8a 8b 8c 8d 8e 8f 8g 8 9a 9b 9c 9d 9e 2 9f 9g 9h 9j 9 CFM Corporation reserves the right to make changes in design materials specifications prices and discontinue colors and products at any time without notice SA18 24 30SHK Series Vented Gas Logs Remote Hearth Kit ...

Page 17: ... Round Front Cross Log 20007806 7e 18 24 30 Cross Log 20007705 8 24 Standard Combination Log Set 20007861 8a 18 24 30 Back Log 20007807 8b 24 Split Right Front 20007808 8c Top Log 3 20008337 8d Top Log 20008336 8e Top Log 20008335 8f 24 30 Cross Log 20007810 8g 24 30 Round Front Cross Log 20007809 9 30 Standard Combination Log Set 20007862 9a 18 24 30 Back Log 20007818 9b 30 Split Left Front 20007...

Page 18: ......

Page 19: ...and components referred to in those paragraphs subject to the following conditions and limitations 1 These warranties are extended only to the Gas Ap pliance installed in the continental United States including Alaska and Canada only if and so long as the accordance with the installation and operating instructions furnished therewith and only if and so long as Gas Appliance is not removed from its...

Page 20: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Corporation ...