6
VCG Biltmore Series • SB100 • 4013-303 Installers Manual • Rev A • 02/19/15
Figure 2.2 Fireplace Locations
NOTICE:
• Illustrations and photos reflect typical installations and
are FOR DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation/appearance may vary due to individual
design preference.
• Vermont Castings Group reserves the right to alter its
products.
NOTICE: In addition to these framing dimensions, also
reference the following section:
• Clearances (Section 3).
NOTICE:
A minimum 1-1/2 in. air clearance at the back and
a minimum 1-1/2 in. air clearance to the sides of
the fireplace assembly must be maintained.
Chimney sections at any level require
a 2 in. minimum air space clearance
between the framing and chimney sec-
tions.
B. Design and Installation Considerations
NOTICE: Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
•
Before installing
, determine the following:
- Where the fireplace is to be installed.
- The vent system configuration to be used.
- Gas supply piping.
- Electrical wiring.
- Framing and finishing details.
- Whether optional accessories - devices such as a
fan, wall switch or remote control - are desired.
1. Selecting Fireplace Locations
This fireplace may be used as a room divider, installed
along a wall, across a corner or used in an exterior chase.
See Figure 2.2.
Locating the fireplace in a basement should be avoided.
Locating near frequently opened doors, central heat
outlets or returns, or other locations of considerable air
movement can affect the performance.
Note:
1-1/2 in. (38 mm) min.
distance from sides & back
of fireplace to combustible
materials. 1/2 in. (13 mm)
min. at nailing flanges.
30-1/2 in.
(775 mm)
77-5/8 in.*
(1972 mm)
1/2 in. (13 mm)
all configurations
In an exterior chase
or projecting into a
garage
Across a
corner
Along a wall
30-1/2 in.
(775 mm)
24 in.
(610 mm)
77-5/8 in.
(1972 mm)
As a room
divider
30-1/2 in.
(775 mm)
48 in.
(1219 mm)
77-5/8 in.
(1972 mm)
52-1/2 in.
(1334 mm)
61-5/8 in.
(1565 mm)
104-7/8in.
(2664 mm)
24-3/8 in.
(619 mm)
74-1/4 in.
(1886 mm)
24 in.
(610 mm)
*
8 in. (203 mm) extra space
included (both sides) for outside
air connection. If outside air duct
has no bend, this dimension
may be reduced as long as
minimum clearances are met.
Consideration should be given to these factors before
deciding on a location.