20303735
39
VWDV70 Series Gas Fireplace
sIGnature coMManD systeM operatIon InstructIons
FunctIons/operatIon
turning on the fireplace
1. Turn on the master switch and wait for a beep.
2. Press the ON button on the Command Center or turn
on wall switch. Pilot will light and burner will come on
High setting or last memory setting (See Turning Off
Fireplace below). For memory feature.
pilot safety Lockout Function
1. If the pilot doesn’t light after sparking for 30 seconds,
pilot trial lockout happens. The LED on the Command
Center flashes Green once every 2 seconds, until re-
set.
2. If the pilot flame is lost during normal operation, the
system will try three (3) times to relight after three (3)
failures, flame loss lockout happens. The LED on the
Command Center flashes Red-Green once every 2
seconds, until reset.
3. Turning the master switch on the Command Center to
the off position, then ON again will reset the system.
Flame height control
1. Press the ON button (on the Command Center) once to
turn on the main burner with maximum flame height.
Fault
LeD Indication
Conversion Cover Missing
One RED (1 time)
Spark Fail
Two RED (1 time)
No Sensor Signal
Three RED (1 time)
Pilot Lockout - trial
One GREEN, every 2 sec. (until manual reset)
Pilot Lockout - flame loss
One RED-GREEN, every 2 sec. (until manual reset)
Low Battery
One RED, every 10s (continuously)
No or Low Thermopile Power
Two RED, every 10s (continuously)
Learning
GREEN Flashes, every 1 sec. (for 10 sec.)
AC Power On
GREEN solid
Pressure Switch Failed (Power Vent only)
One RED every 2 sec. (until manual reset)
self Diagnostics chart:
The Command Center has a self-diagnostic LED enabling
you to troubleshoot problems and potentially avoid a
service call. Please refer to the charts below for indicator
reference.
Function
operation
Power Up
Flip the master switch to the ON ("_") position to power up the system
Fireplace ON
Press the ON
▲
button on the Command Center or turn on wall switch to turn the fireplace on
Fireplace OFF
Flip the master switch to the OFF ("o") position OR press the OFF
▼
button 3
times OR for Memory Off, hold the OFF
▼
button 3 seconds, or turn off wall switch
Flame Height Up
Press the ON
▲
button once to turn on the fireplace with maximum flame height
Flame Height Down
Press the OFF
▼
button to lower the flame height to Medium and Low
2. Press the OFF button to decrease flame height. The first
two presses will decrease the flame height to medium
and low.
3. The third press on OFF will turn off the main burner. In
standing pilot configuration, the pilot will stay; in inter-
mittent pilot configuration, the pilot will be shut off.
turning the Fireplace off
There are three ways to turn the fireplace off.
1. Flip the master switch to the off (“O”) position. (This will
turn the entire system OFF.)
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds or by
turning off the wall switch. These two commands of
OFF are (Memory Off) the system will remember all last
settings before turning off. The next time the fireplace is
turned on, all settings will resume. To reset, change to
the desired settings and shut off by using the Memory
Off commands and the system will be reset to those
new settings.
command center operations:
The following functions are available on the Command
Center.