8
20303735
VWDV70 Series Gas Fireplace
cLearances
6
”
5
”
3
”
4
56O
”
45°
1
”
3
56O
”
FP2423
mantel leg
1
56O
”
2
56O
”
FP2930
Side of
Fireplace Opening
Figure 6 -
Mantel clearances
top View
cLearances to coMBustIBLes
Follow these instructions carefully to ensure
safe installation. Failure to follow instructions
exactly can create a fire hazard.
the appliance cannot be installed on a carpet,
tile or other combustible material other than
wood flooring. If installed on carpet or vinyl
flooring, the appliance shall be installed on
a metal, wood or noncombustible material
panel extending full width and depth of the
appliance.
W
arn
In
G
12”
(305 mm)
12” (305 mm)
FP2422
mantel clearances
Wall
Stud
Standoff
Top of Fireplace
Opening
FP2929
side View
Noncombustible
Material (Supplied)
Figure 5 -
Ceiling and Sidewall Clearances
FP2928
12“ (305 mm)
Max. Depth
12” Min.
From Opening
FP2928
clg sidewall clear
9
56O
”
(241 mm)
30” (762 mm)
Min. to Ceiling
note:
Refer to mantel installation instructions
on
Page 11
.