background image

2

Windsor High Efficiency Wood Stove

30005125

cautiON

After  reading  these  instructions,  if  you  have  any  doubt 

about your ability to complete your installation in a profes-

sional like manner you should obtain the services of an 

installer versed in all aspects as to the correct and safe in-

stallation. Do not use temporary makeshift compromises 

during installation.

before installation of your appliance

1.  Check with the building inspector’s office for compli-

ance with local codes; a permit may be required.

2.  This  appliance  requires  a  masonry  or  prefabricated 

chimney listed to ULC S629 (Canada) and UL103HT 

(U.S.). Sized correctly.

3.  A 6” (152 mm) diameter flue is required for proper per-

formance.

4.  Always  connect  this  unit  to  a  chimney  and 

NEvER

 

vent to another room or inside a building.

5. 

dO NOt

 connect this unit to any duct work to which 

another appliance is connected such as a furnace.

6. 

dO NOt

 connect this unit to a chimney flue serving 

another appliance.

7.  The connector pipe and chimney should be inspected 

periodically and cleaned if necessary.

8.  Remember  the  clearance  distances  when  you  place 

furniture  or  other  objects  within  the  area. 

dO  NOt

 

store  wood,  flammable  liquids  or  other  combustible 

materials too close to the unit.

  Refer to certification label on back of your unit for 

required clearances.

9.  Contact your local municipal or provincial fire authority 

for information on how to handle a chimney fire. Have 

a clearly understood plan to handle a chimney fire. In 

the event of a chimney fire, turn air control to closed 

position and 

call tHE fiRE dEpaRtMENt.

10.

dO NOt

 tamper with combustion air control beyond 

normal adjustment.

Operation precautions

Why the correct flue size is important - 6”

Draft is the force which moves air from the appliance up 

through the chimney. The amount of draft in your chimney 

depends on the length of the chimney, local geography. 

Nearby  obstructions,  and  other  factors.  Too  much  draft 

may cause excessive temperatures in the appliance. An 

uncontrolled burn or a glowing red part or chimney connec-

tor indicates excessive draft. Inadequate draft may cause 

back puffing into the room and “plugging” of the chimney 

and/or cause the appliance to leak smoke into the room 

through appliance and chimney connector joints.

Today’s solid fuel appliances are much more efficient than 

in the past. The units are designed to give you controlled 

combustion, as well as maximum heat transfer, using less 

fuel to do so.
The design of your new appliance is such that the exhaust 

“smoke” is now at lower temperatures than in the past, 

therefore requiring proper chimney size to give adequate 

draft. If your chimney is too large, the heating appliance 

will have a difficult time to raise the “chimney flue” temper-

ature to give adequate draft, therefore causing a smoke 

back up, poor burn or both.

Should you experience such a problem call in a local 

chimney expert.

With the door closed, the rate of burning is regulated by 

the amount of air allowed to enter the unit through the air 

control. With experience you will be able to set the control 

for heat and burning time desired.
Once the required chimney draft is obtained, operate only 

with  doors  closed  and  open  doors  slowly  when  re-fuel-

ing.  (This  will  reduce  or  eliminate  smoke  from  entering 

the room).
Attempts to achieve higher output rates that exceed heat-

er design specifications can result in permanent damage 

to the heater. The recommended wood load is level with 

the top of the firebricks.
Overloading may prevent sufficient air entering the heater 

to properly fuel the fire.
Operate this heater only with the door closed.

dO NOt buRN gaRbagE OR flaMMablE fluidS.
dO NOt uSE cHEMicalS OR fluidS tO StaRt tHE 

fiRE.

tHiS HEatER iS EXtREMEly HOt WHilE iN Op-

ERatiON. 

SERiOuS buRNS caN RESult fROM cONtact.

kEEp  cHildREN,  clOtHiNg  aNd  fuRNituRE 

aWay.

alWayS pROvidE a SOuRcE Of fRESH aiR iNtO 

tHE ROOM WHERE tHE uNit iS iNStallEd. fail-

uRE tO dO SO May RESult iN aiR StaRvatiON 

Of  OtHER  fuEl  buRNiNg  appliaNcES  aNd 

tHE pOSSiblE dEvElOpMENt Of HaZaRdOuS 

cONditiONS.

Optional blower:

 Model S31105

120 V, 60 Hz, 0.75 Amps, 2900 rpm

daNgER: 

Risk of Electric Shock.

Disconnect power before servicing unit. 

iMpORtaNt:

  For optimum heater performance at 

“low” burn rate, operate the fan at low speed.

Summary of Contents for Windsor WR247001

Page 1: ...equirements in your area This stove is listed by OMNI Test Laboratories of Portland Oregon to meet UL1482 for the US and ULC 627 for Canada Do Not Discard This Manual Retain for Future Use 6 Flue requ...

Page 2: ...chimney connec tor indicates excessive draft Inadequate draft may cause back puffing into the room and plugging of the chimney and or cause the appliance to leak smoke into the room through appliance...

Page 3: ...t in an unsafe installation 6 Flue Required A B C D E F G Single wall 10Z x 10Z x 10Z x 19 11Z x 19 54 Connector 267 267 267 483 292 483 1372 Double wall 2Z x 5 2Z x 10Z x 5Z x 10 54 Connector 84 127...

Page 4: ...2 51 mm beyond each side A grouted ceramic floor tile surface installed per local building code considered equivalent Chimney CONTACT YOUR LOCAL BUILDING AUTHORITY FOR APPROVED METHODS OF INSTALLATIO...

Page 5: ...lacing the chimney Regulations specify the chimney must extend 2 610 mm above a 10 3 m radius of the top of the chimney Operation Do not use a grate or elevate fire Build wood fire directly on hearth...

Page 6: ...igh refer to the Inlet Air Control Settings chart 9 When refueling adjust air control to the fully open po sition When fire brightens slowly and carefully open the door This procedure will prevent gas...

Page 7: ...allows wood to achieve the charcoal stage faster and burns wood vapors which might otherwise be deposited with in the system WARNING Things to remember in case of chimney fire 1 Close draft control 2...

Page 8: ...will deposit creosote on the inside of your stove and along the inside of your chimney 3 What does dry seasoned wood mean and what is considered hardwood Wood that has been dried for a period of one y...

Page 9: ...nutes being careful not to over fire If any part of the chimney or parts of the stove start to glow you are over firing the stove Where possible install a temperature gauge on the chimney so temperatu...

Page 10: ...3 Glass and Gasket 1 S31117 3 1 8 Glass Gasket 4 0 S15001 4 5 8 Door Gasket 4 5 S15011 5 Spring Handle 1 90000069 6 Air Control Spring Handle 1 90000070 7 Glass Clip 6 S37034 8 Screw 6 90000286 9 Hing...

Page 11: ...anty If in doubt contact your nearest authorized Vermont Castings Group supplier or Vermont Castings Group Customer Service Department 10 Vermont Castings Group will not be responsible for Down drafts...

Page 12: ...mites d mission pour les po les bois fix es par l agence Am ricaine de protection de l environnement Dans des conditions sp cifiques ce po le d gage entre 11 492 et 18 920 BTU l heure AVIS DE S CURIT...

Page 13: ...NEZ AU SERVICE DES INCENDIES 10 NE TRAFIQUEZ PAS la commande d admission d air au del de son r glage normal Fonctionnement pr caution Pourquoi un conduit d vacuation de 6 po 152 mm Le tirage est le d...

Page 14: ...ction des b timents les dis tances de d gagement minimales respecter 4 Installez des briques r fractaires Fig 2 Assurez vous que toutes les briques sont en place 5 Installez le tuyau fum e L INT RIEUR...

Page 15: ...e fum e 7 Il n est pas n cessaire d avoir de r gulateur de tirage Retirez la plaque de r gulation du tirage install dans la chemin e ou fixez la en position OUVERTE Maison mobile Utiliser seulemnt le...

Page 16: ...le plancher et la chemin e doit passer travers le plafond sans nuire ni l un ni l autre des com posants structuraux du b timent voir les instructions sur l instalaltion de la bouche d air provenant d...

Page 17: ...min e Les r glements indiquent que la chemin e doit avoir 2 pi 610 mm de plus que tout autre objet qui se trouve dans un rayon de 10 pi 3 0 m du dessus de la chemin e Ne br lez pas du bois trait du ch...

Page 18: ...pi ces de remplacement approuv es On remplace un joint de vitre comme suit 1 Assurez vous que l appareil est bien refroidi 2 Enlevez les vis et la bordure de fixation voir sch ma des pi ces 3 Retirez...

Page 19: ...eur voulue et aboutez soigneusement les extr mit s 5 Fermez la porte et laissez s cher la colle durant trois quatre heures avant d utiliser l appareil 3 NE BR LEZ QUE DU BOIS SEC vitez le bois vert Le...

Page 20: ...emarque Plus la commande d admission d air est r gl e un niveau bas plus la combustion de votre bois durera longtemps 2 Quel est le meilleur type de bois qu on peut utiliser dans le po le Vous devriez...

Page 21: ...tre ou une porte poru laisser entrer l air dans la maison b Conditions environnementales Les grands arbres les d pressions comme une vall e les grands difices ou structures adjacents votre maison et...

Page 22: ...la vitre 6 S37018 8 Vis 6 90000286 9 Hinge Pin 2 S11005 10 Push Nut 2 S11090 11 Brique 9 x 4M zn x 1Z v 10 S16040 12 Brique 6Z x x 4M zn x 1Z v 1 S16249 13 Bavette du po le 1 S25078 14 Vis bavette 2 S...

Page 23: ...nnementaux tels que les arbres proximit les difices les toits les collines lesmontagnes ou une concep tion de chemin e inad quate de la ventilation inad quate des d volements excessifs ou de la pressi...

Page 24: ...Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...