background image

3

Windsor High Efficiency Wood Stove

30005125

installation

8”

8”

8”

*16”
**18”

A

B

D

E

C

F

C

F

ST1005
CDW244
clearances
9/08

Figure 1

Clearance from Combustible Materials

Back Wall

Side W

all

Side W

all

Back Wall

clearance to combustible Materials

3.  If noncombustible materials have been installed on the 

walls, obtain the minimum clearances from either the 

manufacturer of these materials or the local building 

inspector’s office.

4.  Install the refractory bricks. (Fig. 2) (Refer also to Page 

11) Be sure all bricks are in place. 

5.  Install the stovepipe INSIDE the flue collar on the top 

of the stove between the stove and chimney.

6. 

dO NOt

 use a grate to elevate the fire.

Unit  must  be  placed  on  a  noncombustible  floor  protection 

equivalent to 3/8” millboard. Floor protector must have min. 

R value of .893. Consult your local building authorities for fur-

ther information.

Contact your local buildng inspector prior to installation. 

A permit may be required in your area.

1.  Remove all parts from inside the stove body.
2.  Select the proper location for the stove. These appli-

ances must not be installed any closer than the mini-

mum  clearance  to  combustible  materials.  shown  in 

Brick pattern (on diagram sheet). The stove must be 

installed  on  a  noncombustible  surface  as  shown  in 

Figure 1.

failure to follow the minimum clearance requirements 

and noncombustible surface requirements may result 

in an unsafe installation.

6” Flue Required

   

F        G

  Single wall 

10

Z\x

”  10

Z\x

”  10

Z\x

”  19”  11

Z\x

”  19” 

54”   

  Connector 

(267)  (267)  (267)  (483)  (292)  (483)  (1372)

  Double wall  2

Z\x

” 

5” 

2

Z\x

”  10

Z\x

”  5

Z\x

”  10” 

54”   

  Connector 

(84)  (127)  (64)  (267)  (140)  (254)  (1372)

34
BRICKLOCATION

Baffle Assembly

Be sure to 

install two (2) full 

bricks (S16040) 

in baffle

ST1019

Figure 2

Brick Placement

Two (2) Full Bricks

* 16” (406 mm) in the US  ** 18” (457 mm) in Canada

parts and tools Required for unpacking 

and assembly

Residential

• 

Single wall connector pipe or listed double wall con-

nector pipe as required

• 

3/8” (10 mm) #6 sheet metal screws to secure connec-

tor pipe

• 

Electric drill with 1/8” (3 mm), 5/32 (4 mm) and 3/16” 

(4.5 mm) drill bits

• 

Screwdriver to secure sheet metal screws

Mobile Home and Outside air Option

In addition to tools required for residential installation you 

will require:

• 

1/4” carbide drill bit

• 

Hammer

• 

A saw capable of cutting a 4” diameter hole. Refer to 

instruction sheet with the outside air kit 

unpacking

Cut and remove strapping bands. Remove cardboard car-

ton, loose parts and packing. 
Inspect stove for possible damage received during ship-

ping.

Stove pipe

1.  A clearance of 18” (457 mm) between the stovepipe 

and  combustible  materials  may  be  required.  Check 

with authorities having jurisdiction in your area.

2.  All pipe sections must be connected with the male end 

(crimped end) toward the stove.

3.  Fasten the stove pipe to the flue collar by the use of 

three (3) sheet metal screws. Do the same at each ad-

ditional joint to make the entire installation rigid.

4.  Maintain the required diameter flue for the entire instal-

lation.

Summary of Contents for Windsor WR247001

Page 1: ...equirements in your area This stove is listed by OMNI Test Laboratories of Portland Oregon to meet UL1482 for the US and ULC 627 for Canada Do Not Discard This Manual Retain for Future Use 6 Flue requ...

Page 2: ...chimney connec tor indicates excessive draft Inadequate draft may cause back puffing into the room and plugging of the chimney and or cause the appliance to leak smoke into the room through appliance...

Page 3: ...t in an unsafe installation 6 Flue Required A B C D E F G Single wall 10Z x 10Z x 10Z x 19 11Z x 19 54 Connector 267 267 267 483 292 483 1372 Double wall 2Z x 5 2Z x 10Z x 5Z x 10 54 Connector 84 127...

Page 4: ...2 51 mm beyond each side A grouted ceramic floor tile surface installed per local building code considered equivalent Chimney CONTACT YOUR LOCAL BUILDING AUTHORITY FOR APPROVED METHODS OF INSTALLATIO...

Page 5: ...lacing the chimney Regulations specify the chimney must extend 2 610 mm above a 10 3 m radius of the top of the chimney Operation Do not use a grate or elevate fire Build wood fire directly on hearth...

Page 6: ...igh refer to the Inlet Air Control Settings chart 9 When refueling adjust air control to the fully open po sition When fire brightens slowly and carefully open the door This procedure will prevent gas...

Page 7: ...allows wood to achieve the charcoal stage faster and burns wood vapors which might otherwise be deposited with in the system WARNING Things to remember in case of chimney fire 1 Close draft control 2...

Page 8: ...will deposit creosote on the inside of your stove and along the inside of your chimney 3 What does dry seasoned wood mean and what is considered hardwood Wood that has been dried for a period of one y...

Page 9: ...nutes being careful not to over fire If any part of the chimney or parts of the stove start to glow you are over firing the stove Where possible install a temperature gauge on the chimney so temperatu...

Page 10: ...3 Glass and Gasket 1 S31117 3 1 8 Glass Gasket 4 0 S15001 4 5 8 Door Gasket 4 5 S15011 5 Spring Handle 1 90000069 6 Air Control Spring Handle 1 90000070 7 Glass Clip 6 S37034 8 Screw 6 90000286 9 Hing...

Page 11: ...anty If in doubt contact your nearest authorized Vermont Castings Group supplier or Vermont Castings Group Customer Service Department 10 Vermont Castings Group will not be responsible for Down drafts...

Page 12: ...mites d mission pour les po les bois fix es par l agence Am ricaine de protection de l environnement Dans des conditions sp cifiques ce po le d gage entre 11 492 et 18 920 BTU l heure AVIS DE S CURIT...

Page 13: ...NEZ AU SERVICE DES INCENDIES 10 NE TRAFIQUEZ PAS la commande d admission d air au del de son r glage normal Fonctionnement pr caution Pourquoi un conduit d vacuation de 6 po 152 mm Le tirage est le d...

Page 14: ...ction des b timents les dis tances de d gagement minimales respecter 4 Installez des briques r fractaires Fig 2 Assurez vous que toutes les briques sont en place 5 Installez le tuyau fum e L INT RIEUR...

Page 15: ...e fum e 7 Il n est pas n cessaire d avoir de r gulateur de tirage Retirez la plaque de r gulation du tirage install dans la chemin e ou fixez la en position OUVERTE Maison mobile Utiliser seulemnt le...

Page 16: ...le plancher et la chemin e doit passer travers le plafond sans nuire ni l un ni l autre des com posants structuraux du b timent voir les instructions sur l instalaltion de la bouche d air provenant d...

Page 17: ...min e Les r glements indiquent que la chemin e doit avoir 2 pi 610 mm de plus que tout autre objet qui se trouve dans un rayon de 10 pi 3 0 m du dessus de la chemin e Ne br lez pas du bois trait du ch...

Page 18: ...pi ces de remplacement approuv es On remplace un joint de vitre comme suit 1 Assurez vous que l appareil est bien refroidi 2 Enlevez les vis et la bordure de fixation voir sch ma des pi ces 3 Retirez...

Page 19: ...eur voulue et aboutez soigneusement les extr mit s 5 Fermez la porte et laissez s cher la colle durant trois quatre heures avant d utiliser l appareil 3 NE BR LEZ QUE DU BOIS SEC vitez le bois vert Le...

Page 20: ...emarque Plus la commande d admission d air est r gl e un niveau bas plus la combustion de votre bois durera longtemps 2 Quel est le meilleur type de bois qu on peut utiliser dans le po le Vous devriez...

Page 21: ...tre ou une porte poru laisser entrer l air dans la maison b Conditions environnementales Les grands arbres les d pressions comme une vall e les grands difices ou structures adjacents votre maison et...

Page 22: ...la vitre 6 S37018 8 Vis 6 90000286 9 Hinge Pin 2 S11005 10 Push Nut 2 S11090 11 Brique 9 x 4M zn x 1Z v 10 S16040 12 Brique 6Z x x 4M zn x 1Z v 1 S16249 13 Bavette du po le 1 S25078 14 Vis bavette 2 S...

Page 23: ...nnementaux tels que les arbres proximit les difices les toits les collines lesmontagnes ou une concep tion de chemin e inad quate de la ventilation inad quate des d volements excessifs ou de la pressi...

Page 24: ...Vermont Castings Group 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com...

Reviews: