4-Wire Conduit Installation

 

(See Figures 2.1, 2.7, 2.8 and 2.10)
1.  Remove the 

Terminal Block Access Plate

 on the back of the 

range by unscrewing the 4 fixing 

Screws

 (fig. 2.1).

2.  Remove the 

Bracket

 and 

Strain Relief

 group by unscrewing 

the 

Bracket Fixing Screws

 (fig. 2.7).

3.  Mount  the 

Conduit  Bracket

  (supplied  with  the  range  in  a 

separate kit) inside the 

Opening For Electrical Connection

 

by screwing the 2 

Fixing Screws

 (as indicated in figure 2.8).

4.  Feed 3/4” (1.90 cm) trade size 

Conduit

 through the hole in the 

Conduit Bracket

 and secure to the 

Conduit Bracket

 with a 

Conduit Clamp

 (fig. 2.10). 

5.  Remove  the  3  wire  terminal  nuts  and  washers  from  the 

Terminal Block

.

6.  Remove  the 

Ground  Strap

  from  the  frame  of  range  and 

terminal  by  removing  its  screw  and  cutting  it  as  shown  in 

figure-2.10.

7.  Plug  the  terminal  holes  of  conductors.  The 

Neutral  Wire

  of 

the 

Power  Cord

  must  be  connected  to  the  neutral  terminal 

located  in  the  center  of 

Terminal  Block

;  the 

Power  Wires

 

must be connected to the outside terminals; the 

Ground Wire

 

must  be  attached  to  the  frame  of  range  by  using  the 

 

(Ground) identified 

Grounding Screw

.

8.  Plug washers and tighten nuts securely.
9.  Assemble the 

Terminal Block Access Plate

.

Conduit

Neutral Wire

Power Wires

Terminal Block

Conduit

Bracket

Grounding Wire

Cut Ground Strap

Grounding Screw

Conduit Clamp

Fig. 2.10

Conduit

Neutral Wire

Power Wires

Terminal Block

Ground strap

Conduit

Bracket

Conduit Clamp

Fig. 2.9

3-Wire Conduit Installation

 

(See Figures 2.1, 2.7, 2.8 and 2.9)
1.  Remove the 

Terminal Block Access Plate

 on the back of the 

range by unscrewing the 4 fixing 

Screws

 (fig. 2.1).

2.  Remove the 

Bracket

 and 

Strain Relief

 group by unscrewing 

the 

Bracket Fixing Screws

 (2.7).

3.  Mount  the 

Conduit  Bracket

  (supplied  with  the  range  in  a 

separate kit) inside the 

Opening For Electrical Connection

 

by screwing the 2 

Fixing Screws

 (as indicated in Figure 2.8).

4.  Feed 3/4” (1.90 cm) trade size 

Conduit

 through the hole in the 

Conduit Bracket

 and secure to the 

Conduit Bracket

 with a 

Conduit Clamp

 (fig. 2.9). 

5.  Remove  the  3  wire  terminal  nuts  and  washers  from  the 

Terminal Block

.

6.  Plug  the  terminal  holes  of  conductors.  The 

Neutral  or 

Ground Wire

 of the 

Power Cord

 must be connected to the 

neutral terminal located in the center of 

Terminal Block

. The 

Power Wires

 must be connected to the outside terminals.

7.  Plug washers and tighten nuts securely.

 

 Do not remove 

Ground strap

.

8.  Assemble the 

Terminal Block Access Plate

.

Strain Relief

Bracket

Bracket

Fixing Screws

Conduit

Bracket

Fixing Screws

Opening For

Electrical

Connection

Fig. 2.7

Fig. 2.8

Summary of Contents for VEFSEE 244 P Series

Page 1: ...nspector s use and for future reference Electrical installation must be in accordance with the National Electrical Code ANSI NFPA70 latest edition and or local codes IN CANADA Electrical installation...

Page 2: ...designed and manufactured solely for the cooking of domestic household food and in not suitable for any none domestic application and therefore should not be used in a commercial environmement The app...

Page 3: ...njury or property damage Consult a qualified installer or a service agent IMPORTANT The use of suitable protective clothing gloves is recommended when handling installing of this appliance INSTALLATIO...

Page 4: ...safety considerations 2 AlI openings in the wall behind the appliance and in the floor under the appliance shall be sealed 3 Keep appliance area clear and free from combustible materials gasoline and...

Page 5: ...bustible surfaces TO THE LEFT above the 36 914 mm high countertop or there must be a minimum of 3 76 mm side clearance from the range to such combustible surfaces TO THE RIGHT above the 36 914 mm high...

Page 6: ...76 mm 13 max 330 mm 914 mm 36 0 0 mm 20 min 500 mm 30 min 457 mm 18 min 762 mm PROXIMITY TO SIDE CABINETS Fig 1 4 ASSEMBLING THE BACKGUARD It is mandatory to install the backguard Assemble the backgua...

Page 7: ...as shown on figure below only rear right side it has to be fixed on the floor and on the rear wall by no 4 four suitable screws not supplied 2 After fixing the anti tip bracket slide range into place...

Page 8: ...wo to three feet of slack in the line so that it can be moved if servicing is ever necessary ELECTRICAL CONNECTION WITH POWER CORD Use a 3 wire power supply cord kit rated for 55 amps 125 250 Volts wi...

Page 9: ...ve the 3 wire terminal nuts and washers from the Terminal Block 4 Plug the terminal holes of Flat Power Cord The Neutral or Ground Wire of the Flat Power Cord must be connected to the neutral terminal...

Page 10: ...ain Relief group by unscrewing the Bracket Fixing Screws fig 2 3 3 Mount the Power Cord Bracket supplied with the range in a separate kit inside the Opening For Electrical Connection by screwing the 2...

Page 11: ...Block Access Plate Conduit Neutral Wire Power Wires Terminal Block Conduit Bracket Grounding Wire Cut Ground Strap Grounding Screw Conduit Clamp Fig 2 10 Conduit Neutral Wire Power Wires Terminal Blo...