11
4-Wire Conduit Installation
(See Figures 2.1, 2.7, 2.8 and 2.10)
1. Remove the
Terminal Block Access Plate
on the back of the
range by unscrewing the 4 fixing
Screws
(fig. 2.1).
2. Remove the
Bracket
and
Strain Relief
group by unscrewing
the
Bracket Fixing Screws
(fig. 2.7).
3. Mount the
Conduit Bracket
(supplied with the range in a
separate kit) inside the
Opening For Electrical Connection
by screwing the 2
Fixing Screws
(as indicated in figure 2.8).
4. Feed 3/4” (1.90 cm) trade size
Conduit
through the hole in the
Conduit Bracket
and secure to the
Conduit Bracket
with a
Conduit Clamp
(fig. 2.10).
5. Remove the 3 wire terminal nuts and washers from the
Terminal Block
.
6. Remove the
Ground Strap
from the frame of range and
terminal by removing its screw and cutting it as shown in
figure-2.10.
7. Plug the terminal holes of conductors. The
Neutral Wire
of
the
Power Cord
must be connected to the neutral terminal
located in the center of
Terminal Block
; the
Power Wires
must be connected to the outside terminals; the
Ground Wire
must be attached to the frame of range by using the
(Ground) identified
Grounding Screw
.
8. Plug washers and tighten nuts securely.
9. Assemble the
Terminal Block Access Plate
.
Conduit
Neutral Wire
Power Wires
Terminal Block
Conduit
Bracket
Grounding Wire
Cut Ground Strap
Grounding Screw
Conduit Clamp
Fig. 2.10
Conduit
Neutral Wire
Power Wires
Terminal Block
Ground strap
Conduit
Bracket
Conduit Clamp
Fig. 2.9
3-Wire Conduit Installation
(See Figures 2.1, 2.7, 2.8 and 2.9)
1. Remove the
Terminal Block Access Plate
on the back of the
range by unscrewing the 4 fixing
Screws
(fig. 2.1).
2. Remove the
Bracket
and
Strain Relief
group by unscrewing
the
Bracket Fixing Screws
(2.7).
3. Mount the
Conduit Bracket
(supplied with the range in a
separate kit) inside the
Opening For Electrical Connection
by screwing the 2
Fixing Screws
(as indicated in Figure 2.8).
4. Feed 3/4” (1.90 cm) trade size
Conduit
through the hole in the
Conduit Bracket
and secure to the
Conduit Bracket
with a
Conduit Clamp
(fig. 2.9).
5. Remove the 3 wire terminal nuts and washers from the
Terminal Block
.
6. Plug the terminal holes of conductors. The
Neutral or
Ground Wire
of the
Power Cord
must be connected to the
neutral terminal located in the center of
Terminal Block
. The
Power Wires
must be connected to the outside terminals.
7. Plug washers and tighten nuts securely.
Do not remove
Ground strap
.
8. Assemble the
Terminal Block Access Plate
.
Strain Relief
Bracket
Bracket
Fixing Screws
Conduit
Bracket
Fixing Screws
Opening For
Electrical
Connection
Fig. 2.7
Fig. 2.8