background image

Application  Guide 

 
 

 
 

65 

4. Select a member port and a block port for this central block switch. 

 
 

Balance Chain –Terminal-1 and -2 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. Go to “Configuration

à

  “

RingV2” Web page

 

2. Disable Index1 and Index2, then enable Index3

 

3. Select Role to “Balancing Chain(Terminal-1 or -2)” 
4. Select a member port and a terminal port for this balancing chain terminal switch. 

Summary of Contents for VX-IGP-1204F

Page 1: ...1 VX IGP 1204F 8 14 Port Managed Industrial Ethernet Switch User Guide Version Number 1 0 Issue 1 2r1 July 2015 ...

Page 2: ...t to Default and Save Configure 25 LED STATUS INDICATIONS 28 VLAN Application Guide 31 Example 1 Default VLAN Settings 31 Example 2 Port based VLANs 32 Example 3 IEEE 802 1Q Tagging 35 Security Application Guide 38 Case 1 ACL for MAC address 38 Case 2 ACL for IP address 54 Case 3 ACL for L4 Port 54 Case 4 ACL for ToS 54 Ring Version 2 Application Guide 55 Ring Version 2 Feature 56 How to Configure...

Page 3: ...eset 94 LIST OF TABLES Table 1 LED Status Indicators 28 LIST OF FIGURES Figure 1 VX IGP 1204F00 DIN Rail Mounting 13 Figure 2 VX IGP 1204F00 Wall Mounting 14 Figure 3 LED Indicators 29 Preface Scope Audience Safety Instructions Documentation Conventions ...

Page 4: ...power The primary hazards of exposure to laser radiation from an optical fiber communication system are Damage to the eye by accidental exposure to a beam emitted by a laser source Damage to the eye from viewing a connector attached to a broken fiber or an energized fiber Documentation Conventions The following conventions are used in this manual to emphasize information that will be of interest t...

Page 5: ...5 Overview Overview Faceplate Panel Introduction Technical Specifications ...

Page 6: ...Ethernet solutions deliver high quality wide operation temperature range extended power input range and advanced VLAN QoS features It s ideal for harsh environments and mission critical applications Faceplate 8 Port series 10 Port series ...

Page 7: ...7 8 10 Port PL series 12 Port PL series VX IGP 1204F ...

Page 8: ...us LED P1 P2 and Alarm Gigabit Ethernet Copper Ports RJ45 Gigabit Ethernet SFP ports SFP Slots POE LED POE port status RR RS LED Device info status Top Panel Introduction Top Panel Power Input Dual 6P Terminal Block Console RS232 RJ45 Reset Push Button ...

Page 9: ... Static trunk or Dynamic via LACP Link Aggregation Control Protocol Bridge VLANs Protocols Flow control IEEE 802 3x Full Duplex and Back Pressure Half Duplex VLAN Types Port based VLANs IEEE 802 1Q tag based VLANs IEEE 802 1ad Double Tagging Q in Q Multicast protocols IGMP v1 v2 IGMP snooping and querying Immediate leave and leave proxy Throttling and filtering LLDP IEEE 802 1ab Link layer Discove...

Page 10: ...SFP with DDM Digital Diagnostic Monitoring MIBs RMON 1 2 3 9 Q Bridge MIB RFC 1213 MIB II RFC 4188 Bridge MIB DHCP Client Server Relay Snooping Option 82 NTP SNTP Yes Environmental Compliances Operating temperature range 40 to 75 C cold startup at 40 C Storage temperature range 40 to 85 C Humidity non condensing 5 to 95 RH Vibration shock freefall IEC68 2 6 27 32 Certification compliance CE FCC EN...

Page 11: ... Code 255 RADIUS Server 5 TACACS Server 5 MAC based VLAN Entry 256 IP subnet based VLAN Entry 128 Protocol based VLAN Group 125 Voice VLAN OUI 16 QCE 256 IP Interface 8 IP Route 32 Security Access Management 16 MVR VLAN 4 MAC Learning table address 8k IGMP Group 256 ...

Page 12: ...12 Quick Installation Equipment Mounting Cable Connecting Equipment Configuration ...

Page 13: ...Rail Mounting step 1 Screw the DIN Rail bracket on with the bracket and screws in the accessory kit 2 Hook the unit over the DIN rail 3 Push the bottom of the unit towards the DIN Rail until it snaps into place Figure 1 VX IGP 1204F DIN Rail Mounting 1 2 ...

Page 14: ...14 Mounting the VX IGP 1204F Wall mount Mounting step 1 Screw on the wall mounting plate on with the plate and screws in the accessory kit Figure 2 VX IGP 1204F Wall Mounting ...

Page 15: ...15 Ground Connections VX IGP 1204F must be properly grounded for optimum system performance ...

Page 16: ...ht through or a cross over Ethernet cable To connect the VX IGP 1204F copper Port to an Ethernet device use UTP Unshielded Twisted Pair or STP Shielded Twisted Pair Ethernet cables The pin assignment of RJ 45 connector is shown in the following figure and table VX IGP 1204Fxx series Pin Assignment 1 2 T Rx T Rx 3 6 T Rx T Rx 4 5 T Rx T Rx 7 8 T Rx T Rx VX IGP 1204F ...

Page 17: ...al operational LED status Fiber optics cable with LC duplex connector Connect the optical fiber to the SFP socket DANGER Never attempt to view optical connectors that might be emitting laser energy Do not power up the laser product without connecting the laser to the optical fiber and putting the cover in position as laser outputs will emit infrared laser light at this point Pin Assignment PoE Ass...

Page 18: ... polarity signs on the top panel The VX IGP 1204F can be powered from two power supply input range 12V 58V The DC power connector is a 6 pin terminal block There is alarm contact on the middle terminal block Refer to Table 1 for the normal operational LED status VX IGP 1204F ...

Page 19: ...cal management by using a terminal emulator or a computer with terminal emulation software DB9 connector connect to computer COM port Baud rate 115200bps 8 data bits 1 stop bit None Priority None flow control Power Connector 6P Terminal Block Input DC 12 58V PWR1 Power Input 1 PWR2 Power Input 2 ALM Alarm relay output ...

Page 20: ...P 1204F the DB9 connector of the cable is connected to the PC COM port The pin assignment of the Console cable is shown below SYSTEM RESET The Reset button is provided to reboot the system without the need to remove power Under normal circumstances you will not have to use it However or rare occasions the VX IGP 1204F may not respond then you may need to push the Reset button Reset Button ...

Page 21: ...ed Web page font Times New Roman Plain text font Courier New Encoding Unicode UTF 8 Text size Medium Firefox with the following default settings is recommended Web page font Times New Roman Encoding Unicode UTF 8 Text size 16 Google Chrome with the following default settings is recommended Web page font Times New Roman Encoding Unicode UTF 8 Text size Medium ...

Page 22: ...22 Connect Login to VX IGP 1204F00 1 Connecting to VX IGP 1204F Ethernet port RJ45 Ethernet port 2 Factory default IP 192 0 2 1 3 Login with default account and password Username admin Password none ...

Page 23: ...t RJ45 Ethernet port 2 Key in the command under Telnet telnet 192 0 2 1 3 Login with default account and password Username admin Password none 4 Change the IP with commands listed below CLI Command enable configure terminal interface vlan 1 ip address xxx xxx xxx xxx xxx xxx xxx xxx exit ...

Page 24: ...atus By SFP Refer to Figure 3 for monitoring 4 Gigabit Ethernet with SFP connector Also refer to Table 1 for the normal operational LED status Up Downgrade Software 1 In Web UI go to MaintenanceàSoftwareàUpload page 2 Select software file and click Upload button 3 After starting to upload software to device please don t cold warm start device and wait it auto reboot then upgrade finished ...

Page 25: ...s command reload defaults keep ip 2 check interface VLAN and IP address confirm only management IP setting kept 3 Execute this command copy running config startup config If manager want to reset the all configuration to default completely 1 please execute this command reload defaults 2 check interface VLAN and IP address confirm they all change to default setting 3 Execute this command copy runnin...

Page 26: ...pagination to Click Yes button 2 Go to Maintenance à Configuration à Save startup config pagination then click Save Configuration button then reset successfully If manager want to reset the all configuration to default completely 1 Go to Maintenance à Configuration à Activate pagination to select default config then click Activate Configuration button ...

Page 27: ...ess belong to 192 0 2 X networks 3 Change WEB s IP be 192 0 2 1 default IP to login DUT s Web UI 4 Go to Maintenance à Configuration à Save startup config pagination then click Save Configuration button then reset successfully ...

Page 28: ...en Ethernet link up and there is traffic detected Off Ethernet link down Copper ports Speed On Yellow A 100 Mbps or a 1000Mbps connection is detected Off No link or a 10 Mbps connection is detected SFP port Link Act SFP port Link Act On Green On Green Ethernet link up Ethernet link up Off Off Ethernet link down Ethernet link down SFP port SFP port Spee Speed d On Yellow On Yellow SFP port speed 10...

Page 29: ...29 Figure 3 LED Indicators PWR LED Indicator ALM LED Indicator Copper Link Act LED Copper Speed LED SFP Speed LED Indicator SFP Link LED Indicator ...

Page 30: ...30 Application Guide VLAN Application Guide Security Application Guide Ring Protection Application Guide QoS Application Guide Link Fail Alarm Application Guide 802 1x Authentication Application Guide ...

Page 31: ...d only to ports in the same VLAN Example 1 Default VLAN Settings Each port in the VX IGP 1204F has a configurable default VLAN number known as its PVID This places all ports on the same VLAN initially although each port PVID is configurable to any VLAN number between 1 and 4094 The default configuration settings for VX IGP 1204F have all ports set as untagged members of VLAN 1 with all ports confi...

Page 32: ...llowing figure the untagged packet is marked tagged as it leaves the VX IGP 1204F through Port 2 which is configured as a tagged member of VLAN100 The untagged packet remains unchanged as it leaves the VX IGP 1204F through Port 7 which is configured as an untagged member of VLAN100 Configuration Step1 Go to Configuration VLANs Port VLAN configuration and configure PVID 100 on Port 1 Port 2 and Por...

Page 33: ...tep4 Transmit untagged unicast packets from Port 1 to Port 2 and Port 7 The VX IGP 1204F should tag it with VID 100 The packet has access to Port2 and Port 7 The outgoing packet is stripped of its tag to leave Port 7 as an untagged packet For Port 2 the outgoing packet leaves as a tagged packet with VID 100 Step5 Transmit untagged unicast packets from Port 2 to Port 1 and Port 7 The VX IGP 1204F s...

Page 34: ...rt trunk vlan tag native switchport mode trunk exit interface GigabitEthernet 1 2 switchport access vlan 100 switchport trunk native vlan 100 switchport trunk allowed vlan 1 100 switchport trunk vlan tag native switchport mode trunk exit interface GigabitEthernet 1 7 switchport access vlan 100 switchport trunk native vlan 100 switchport trunk allowed vlan 1 100 switchport mode trunk exit ...

Page 35: ...LAN 200 because of the tag assignment in the packet Port 2 is configured as a tagged member of VLAN 100 and Port 7 is configured as an untagged member of VLAN 200 Hosts in the same VLAN communicate with each other as if they in a LAN However hosts in different VLANs cannot communicate with each other directly In this case 1 The hosts from Group A can communicate with each other 2 The hosts from Gr...

Page 36: ...d tag it with VID 200 The packet only has access to Port7 The outgoing packet on Port 7 is stripped of its tag as an untagged packet Step4 Transmit unicast packets with VLAN tag 100 from Port 2 to Port 1 and Port 7 The VX IGP 1204F should tag it with VID 100 The packet only has access to Port1 For Port 1 the outgoing packet leaves as a tagged packet with VID 100 Step5 Transmit unicast packets with...

Page 37: ...trunk vlan tag native switchport mode trunk exit interface GigabitEthernet 1 1 switchport access vlan 100 switchport trunk allowed vlan 1 100 switchport trunk vlan tag native switchport mode trunk exit interface GigabitEthernet 1 7 switchport access vlan 100 switchport trunk allowed vlan 1 200 switchport trunk vlan tag native switchport mode trunk exit ...

Page 38: ... permit frames set in ACL entry h Deny all frames i Deny all frames j Deny all frames but to copy frame which set in ACL entry to a defined GE port Case 1 ACL for MAC address For MAC address ACL it can filter on source MAC address destination MAC address or both When it filters on both MAC address packets coincident with both rules will take effect In other words it does not do filter if it only c...

Page 39: ...ional MAC address with one VLAN deny filtering Step 1 Create a new ACL Profile Profile Name DenySomeMac Step 2 Create a new ACL Entry rule under this ACL profile Deny MAC 11 and VLAN 4 Step 3 Bind this ACL profile to a GE port PORT 4 ...

Page 40: ...gabitEthernet 1 4 policy 1 vid 4 frametype etype smac 00 00 00 00 00 11 action deny exit interface GigabitEthernet 1 3 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native interface GigabitEthernet 1 4 switchport trunk allowed vlan 4 5 switchport trunk vlan tag nativevlan 4 exit VX IG P 1204 F VX IG P 1204 F VX IG P 1204 F ...

Page 41: ...al MAC address with all VLAN deny filtering Step 1 Create a new ACL Profile Profile Name DenySomeMac Step 2 Create a new ACL Entry rule under this ACL profile Deny SrcMAC 13 and DesMAC 11 Step 3 Bind this ACL profile to a GE port PORT 3 ...

Page 42: ...rnet 1 3 policy 0 frametype etype smac 00 00 00 00 00 13 dmac 00 00 00 00 00 11 action deny exit interface GigabitEthernet 1 3 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native interface GigabitEthernet 1 4 switchport trunk allowed vlan 4 5 switchport trunk vlan tag nativevlan 4 exit VX IG P 1204 F VX IG P 1204 F VX IG P 1204 F ...

Page 43: ...s port l Case 1 d User can set default ACL Rule of GE port as Permit then to bind a suitable profile with CoS Marking action for some ACL function It means GE port can remark CoS of the VLAN frame received from this port One directional MAC address with CoS Marking action one VLAN and don t care Ether Type Step 1 Create a new ACL Profile Profile Name CoSMarkingTest Step 2 Create a new ACL Entry ru...

Page 44: ...ace GigabitEthernet 1 4 policy 1 vid 4 frametype etype smac 00 00 00 00 00 11 action deny exit interface GigabitEthernet 1 3 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native interface GigabitEthernet 1 4 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native exit VX IG P 1204 F VX IG P 1204 F VX IG P 1204 F ...

Page 45: ...will copy frames from binding GE Port to analyzer port Two directional MAC address with Copy Frame action Don t care VLAN ID Ether Type Step 1 Create a new ACL Profile Profile Name CopyFrameTest Step 2 Create a new ACL Entry rule under this ACL profile SrcMAC 13 and DesMAC 11 Step 3 Set analyzer port to enable and mirror analyzer port Step 4 Bind this ACL profile to a GE port PORT 3 ...

Page 46: ...0 frametype etype smac 00 00 00 00 00 13 dmac 00 00 00 00 00 11 action deny mirror redirect interface GigabitEthernet 1 5 exit interface GigabitEthernet 1 3 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native interface GigabitEthernet 1 4 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native exit VX IG P 1204 F VX IG P 1204 F VX IG P 1204 F ...

Page 47: ...rofile with Permit action for ACL It means GE port can not pass through all packets but ACL entry of the profile binding One directional MAC address with one VLAN permit filtering Step 1 Create a new ACL Profile Profile Name AllowSomeMac Step 2 Create a new ACL Entry rule under this ACL profile Allow MAC 11 and VLAN 4 Step 3 Bind this ACL profile to a GE port PORT 4 ...

Page 48: ... GigabitEthernet 1 4 policy 3 tag tagged vid 4 frametype etype smac 00 00 00 00 00 11 exit interface GigabitEthernet 1 3 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native interface GigabitEthernet 1 4 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native exit VX IG P 1204 F VX IG P 1204 F VX IG P 1204 F ...

Page 49: ... MAC address with all VLAN permit filtering Step 1 Create a new ACL Profile Profile Name AllowSomeMac Step 2 Create a new ACL Entry rule under this ACL profile Allow SrcMAC 13 and DesMAC 11 Step 3 Bind this ACL profile to a GE port PORT 3 ...

Page 50: ...bitEthernet 1 3 policy 5 frametype etype smac 00 00 00 00 00 13 dmac 00 00 00 00 00 11 exit interface GigabitEthernet 1 3 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native interface GigabitEthernet 1 4 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native exit VX IG P 1204 F VX IG P 1204 F VX IG P 1204 F ...

Page 51: ...rofile with Copy Frame action for mirror analyzer used It means the system will copy frames from binding GE Port to analyzer port There is no frame received from the denied GE port but the mirror analyzer port One directional MAC address with Copy Frame action Don t case VLAN Ether Type Step 1 Create a new ACL Profile Profile Name CopyFrameTest Step 2 Create a new ACL Entry rule under this ACL pro...

Page 52: ...Application Guide 52 Step 5 Send frames between PORT 3 and PORT 4 see test result VX IG P 120 4F VX IG P 120 4F VX IG P 120 4F ...

Page 53: ...c 00 00 00 00 00 13 dmac 00 00 00 00 00 11 Exit monitor destination interface GigabitEthernet 1 5 monitor source cpu both exit interface GigabitEthernet 1 3 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native interface GigabitEthernet 1 4 switchport trunk allowed vlan 4 5 switchport trunk vlan tag native exit ...

Page 54: ...t should select exact one Protocol from UDP or TCP When it filters on both directional IP address and L4 port packets coincident with both rules will take effect In other words it does not do filter if it only coincident with one rule If user wants to filter only one directional IP address or L4 port the other IP address and L4 port just set to all zero It means don t care portion The detail testi...

Page 55: ...ant to Ethernet applications especially in Industrial domain Versa Technology s VX IGP 1204F provides a mini second grade failover ring protection this feature offers a seamless working network even if encountering some matters with connections It is able to be applied by Ethernet cable and Fiber ...

Page 56: ...s ring slave both ring ports are forward port Group 2 It support configuration of the ring coupling and dual homing Ring it could be master or slave Coupling it could be primary and backup When role is coupling primary only it need configure one ring port named primary port When role is coupling backup only it need configure one ring port named backup port This backup port is redundant port In nor...

Page 57: ... and balancing chain Chain it could be head tail or member When role is chain head one ring port is head port and another is member port Both ring ports are forwarded in normal state When role is chain tail one ring port is tail port and another is member port The tail port is redundant port It is blocked in normal state When role is chain member both ring ports are member port Both ring ports are...

Page 58: ...ing chain terminal 1 2 one ring port is terminal port and another is member port Both ring ports are forwarded in normal state When role is balancing chain member both ring ports are member port Both ring ports are forwarded in normal state Note 1 It must enable group1 before configure group2 as coupling Note 2 When group1 or group2 is enabled the configuration of group3 is invisible Note 3 When g...

Page 59: ...connect with other switch For example choose PORT 1 and PORT 2 that means PORT 1 is one of the ports connected with other switch so is PORT 2 Then choose one of ring connection devices be Master which you can accept the Node 2 port be blocking port node1 interface GigabitEthernet 1 1 node2 interface GigabitEthernet 1 2 role ring master Configure finish must enable ring protection status by by comm...

Page 60: ...ing coupling dual homing chain and balancing chain Note 1 It must enable group1 before configure group2 as coupling Note 2 When group1 or group2 is enabled the configuration of group3 is invisible Note 3 When group3 is enabled the configuration of group1 and group3 is invisible First Step Disable RSTP on All Ring Port 1 Go to ConfigurationàSpanning Treeà CIST ports Web page 2 Do not enable STP glo...

Page 61: ...Select one port as a Forward Port another is Block Port Ring Slave 1 Go to Configurationà RingV2 Web page 2 Enable Index1 and Select Role as Ring Slave 3 Select two ports as Forward Port Coupling Primary 1 Go to Configurationà RingV2 Web page 2 Enable Index1 and Select Role as Ring Slave 3 Select two ports as Forward Port ...

Page 62: ...ct Role as Ring Slave 3 Select two ports as a Forward Port 4 Enable Index2 and Select Role as Coupling Backup 5 Select one port as a Backup Port Dual Homing 1 Go to Configurationà RingV2 Web page 2 Enable Index1 and Select Role as Ring Slave 3 Select two ports as a Forward Port 4 Enable Index2 and Select Role as Dual Homing 5 Select one port as a Primary Port and the other is Backup Port ...

Page 63: ...x1 and Index2 then enable Index3 3 Select Role to Chain Member 4 Select two member ports for this chain member switch Chain Head 1 Go to Configurationà RingV2 Web page 2 Disable Index1 and Index2 then enable Index3 3 Select Role to Chain Head 4 Select a member port and a head port for this chain head switch ...

Page 64: ...then enable Index3 3 Select Role to Chain Tail 4 Select a member port and a tail port for this chain tail switch Balance Chain Configuration Balance Chain Central Block 1 Go to Configurationà RingV2 Web page 2 Disable Index1 and Index2 then enable Index3 3 Select Role to Balancing Chain Central Block ...

Page 65: ... central block switch Balance Chain Terminal 1 and 2 1 Go to Configurationà RingV2 Web page 2 Disable Index1 and Index2 then enable Index3 3 Select Role to Balancing Chain Terminal 1 or 2 4 Select a member port and a terminal port for this balancing chain terminal switch ...

Page 66: ...s its CoS queue User needs to bind VLAN priority queue mapping profile to each port for every VLAN priority need assign a traffic descriptor for it The traffic descriptor defines the shape parameter on every VLAN priority for Ethernet interface Currently KGS supports Strict Priority and SP WRR Weighted Round Robin scheduling methods on each port Please find the detail reference on VX IGP 1204F use...

Page 67: ...xpected Result We expect PORT 2 only can receive 100Mbps of Stream1 and Stream0 will be discarded This case will help user to know how SPQ works on the VX IGP 1204F Gigabit port VLAN Priority Queue mapping l Stream0 Dst Mac 00 00 00 00 20 01 Src Mac 00 00 00 00 10 01 Vlan 100 Vlan prio 0 Send rate 100Mbps Packet length 1518bytes l Stream1 Dst Mac 00 00 00 00 20 02 Src Mac 00 00 00 00 10 02 Vlan 10...

Page 68: ...gement Step1 Go to Configuration Ports set port 2 link speed to 100Mbps full duplex Step2 Select Configuration VLANs Create a VLAN with VLAN ID 100 Enter a VLAN name in the Name field Here we set tagged VLAN100 on PORT 1 and PORT 2 ...

Page 69: ... switchport trunk native vlan 100 switchport trunk allowed vlan 1 100 switchport trunk vlan tag native switchport mode trunk interface GigabitEthernet 1 2 switchport trunk native vlan 100 switchport trunk allowed vlan 1 100 switchport trunk vlan tag native switchport mode trunk ...

Page 70: ...ic are not flooding Expected Result We expect PORT 2 only can receive 20Mbps of Stream1 and 80Mbps of Stream0 This case will help user to know how SPQ works on the VX IGP 1204F VDSL port VLAN Priority Queue mapping l Stream0 Dst Mac 00 00 00 00 20 01 Src Mac 00 00 00 00 10 01 Vlan 100 Vlan prio 0 Send rate 100Mbps Packet length 1518bytes l Stream1 Dst Mac 00 00 00 00 20 02 Src Mac 00 00 00 00 10 0...

Page 71: ...01 Vlan 100 Vlan prio 0 Send rate 10Mbps Packet length 1518bytes l Stream4 for Learning Dst Mac 00 00 00 00 10 02 Src Mac 00 00 00 00 20 02 Vlan 100 Vlan prio 0 Send rate 10Mbps Packet length 1518bytes Web management Step1 Go to Configuration Qosà Port Shaping to create a Qos profile on Port 2 ...

Page 72: ...ng rate for queue 0 and queue 7 as below CLI configuration command interface GigabitEthernet 1 2 switchport trunk native vlan 100 switchport trunk allowed vlan 1 100 switchport trunk vlan tag native switchport mode trunk qos queue shaper queue 0 80000 qos queue shaper queue 7 20000 ...

Page 73: ...t routers to establish multicast group memberships It is an integral part of the IP multicast specification like ICMP for unicast connections IGMP can be used for online video and gaming and allows more efficient use of resources when supporting these uses Example 1 If administrator every client could get multicast stream just go to ConfigurationàIPMCàBbasic Configuration to select the check box o...

Page 74: ...74 ...

Page 75: ... of Snooping Enable 2 Un select the check box of Unregistered IPMCv4 Flooding Enabled 3 If Multicast stream is from L3 switch then the uplink port have to be Router Port Notice If an aggregation member port is selected as a router port the whole aggregation will act as a router port ...

Page 76: ...76 4 Go to ConfigurationàIPMCàVLAN Configuration to select the check box of Snooping Enable and set VLAN ID of port14 ...

Page 77: ...77 ...

Page 78: ...scenario these clients belong to multiple vlans you have to create more one vlan to be the agent for all client vlans 1 To create a vlan go to ConfigurationàVLANsàAllow Access VLANs then set port 14 be vlan200 member port ...

Page 79: ... the check box of Snooping Enable and set VLAN ID of port14 3 If there is no querier on the L3 switch you have to select Querier Election and set the Querier Address the IP address is in the same network as uplink interface 4 Selecet the IGMP version as server ...

Page 80: ...80 How to Configuration VLC VLC Configure on IGMP Server 1 In Media area of top tool bar to select Stream 2 Select a video or voiced file to play ...

Page 81: ...81 3 Confirm the file is right then click Next twice ...

Page 82: ...82 4 Select stream type as UDP and click Add button 5 Set stream IP the range is 224 0 0 1 to 239 255 255 254 and protocol port is 1234 Here I set stream IP is 255 0 0 1 ...

Page 83: ...83 6 Select Sort out all stream and click Stream button then the stream start to send to switch VLC Configure on IGMP Client 1 In Media area of top tool bar to select open network stream ...

Page 84: ...rotocol port as previous setting on server the protocol type is UDP the format should as below circle then click PLAY button Back to management switch Go to Monitorà IPMCà Groups Information you will see the stream IP in the table ...

Page 85: ...any service from the network Please see the following description 802 1x Timer in VX IGP 1204F Item Parameter sec Description 1 ReAuth Period VX IGP 1204F will restart authentication after each Reauth Period when authentication success and ReAuth option is enabled 2 Quiet Period VX IGP 1204F will wait QuietPeriod to restart authentication process again when authentication failed in previous time 3...

Page 86: ...86 Step 2 Edit secret key for Radius server Setting client 20 20 20 0 24 secret a1b2c3d4 The secret in the VX IGP 1204F should be the same with this one ...

Page 87: ...hentication via VX IGP 1204F to be authenticated by RADIUS server In a basic example we take port 1 as a testing port which enables 802 1x in VX IGP 1204F With default configuration use the following Web UI setting Step1 Go to Configuration Security Networks NAS Select Enable mode to enable authentication and set port 1 port 2 be Port Base 802 1x test123 Cleartext Password test123 aaaa Cleartext P...

Page 88: ...88 Step1 Go to Configuration Security AAA Radius Click Add New Server Input 20 20 20 20 for server and a1b2c3d4 for secret key Then click Save button ...

Page 89: ...ation Enable check box then to configure EAP type to MD5 Challenge After setting this function in NIC supplicant should enter a correct pair of account and password in order to use this Ethernet port service from VX IGP 1204F Configure ter interface vlan 1 ip address 20 20 20 120 255 0 0 0 exit exit radius server host 20 20 20 20 timeout 5 retransmit 3 key a1b2c3d4 dot1x re authentication dot1x sy...

Page 90: ...should pass authentication process in order to use any service After supplicant enters correct account and password which stored in RADIUS server it can be authenticated successfully The authentication process is as following VX IGP 120 4F ...

Page 91: ...wer Determination There are three modes for configuring how the ports PDs may reserve power 1 Class mode In this mode each port automatically determines how much power to reserve according to the class the connected PD belongs to and reserves the power accordingly Five different port classes exist and one for 4 7 15 4 or 30 Watts 2 Allocated mode In this mode the user allocates the amount of power...

Page 92: ...r that port The ports are shut down according to the ports priority If two ports have the same priority the port with the highest port number is shut down Port Priority Critical High Low When priorities are the same low number of the port has higher priority 2 Reserved Power In this mode the ports are shut down when total reserved powered exceeds the amount of power that the power supply can deliv...

Page 93: ...t The option is only available when following rules are applied High power switch model supports Only port1 or port2 supports Current operation mode is 802 3at Enable Enable 4Pairs to support 60W Disable Disable 4Pairs to limit 30W of power 5 PoE Priority The Priority represents the ports priority There are three levels of power priority named Low High and Critical The priority is used in the case...

Page 94: ...erval Check or uncheck as needed to modify the scheduling table 1 Day Checkmarks indicate which day are members of the set From Sunday to Saturday 2 Interval Start Select the start hour and minute End Select the end hour and minute There are 48 time interval one day Each interval has 30 minutes 3 Action Power On Select the radio button to apply power on during the interval Power Off Select the rad...

Page 95: ... 3 802 3af with low priority 3 PD Power Consumption Port 1 1 3 watt PoE Splitter Port 2 1 3 watt PoE VoIP Phone Port 3 3 8 watt PoE WiFi AP 4 Web Configuration 5 Test Result PoE port status can be monitored by Web MonitoràPoE In the following table it can be seen if system budget is not enough for all PoE device port with higher priority port will be feed power first The last priority port port 3 ...

Page 96: ... 30 W Port 2 Port8 15 4 W Total 137 8 W 3 PD Power Consumption Port 1 1 3 watt PoE Splitter Port 2 1 3 watt PoE VoIP Phone Port 3 3 8 watt PoE WiFi AP 4 Web Configuration 5 Test Result PoE port status can be monitored by Web MonitoràPoE Since power has reserved for each port in advance each powered device can use power budget of its corresponding port without exceed its maximum power ...

Reviews: