Example 1
1.
Parameter Setting:
Reserved Power determined: Class
Power Management Mode: Actual Consumption
Primary Power Supply: 6W
2.
Test Port
Port 1: 802.3at with critical priority
Port 2: 802.3af with high priority
Port 3: 802.3af with low priority
3.
PD Power Consumption
Port 1: 1.3 watt (PoE Splitter)
Port 2: 1.3 watt (PoE VoIP Phone)
Port 3: 3.8 watt (PoE WiFi AP)
4.
Web Configuration
5.
Test Result
PoE port status can be monitored by Web: Monitor
à
PoE
In the following table, it can be seen if system budget is not enough for all PoE device, port with
higher priority port will be feed power first. The last priority port (port 3) will not be powered.