165
P
LANTING
R
ATE
C
ONTROL
Note: The Rate buttons in the Product Control Toolbox at top right are explained in
P
RODUCT
C
ONTROL
T
OOLBOX
During SeedCommand Run Time operations, the Product Tabs are
shown in the upper right-hand side of the Map screen. Press the
Product Tabs, and an extended view shows the Rate buttons, Manual
Valve Control button, Prescription button, Rate increase and decrease
arrows
/
, and the Rate Setup button, all of which are
described below.
• (A) Variety
The Product Control Toolbox can show rates for multiple varieties,
depending upon the particular planting configuration. Press the area of the
box that shows a particular variety, and a green bar highlights that variety.
The Rate 1 and Rate 2 are then shown on the Rate buttons.
• (B) Target Rate
• (C) Actual Rate
Two items, Target Rate and Actual Rate, appear on each Product Tab shown in the Product Control
Toolbox. The
Target Rate
is the desired planting rate. The
Actual Rate
is communicated by the shaft
rotation sensor.
Note: In some conditions, the Actual Rate may increment slower than the Target Rate, or its numeric values
may vary before matching the Target Rate.
• (D) Manual Valve Control
The Manual Valve Control button allows operators to specify the position of the control
valve. Operators use this option to clean out equipment at the end of the day.
• (E) Prescription button
For more information, see
“Loading Prescriptions” on page 166
.
• (F) Rate 1 button
• (G) Rate 2 button
These only appear on Hydraulic Drive or Stepper Seed Meter configurations. The
Rate 1 and Rate 2 settings represent preset planting rates that allow operators to quickly change
between desired planting rates for each individual product. The active rate button appears with a gray
background behind it. In the example above, Rate 1 is active.
• (H) Rate Increase arrow
• (I) Rate Decrease arrow
Pressing once on
/
increments the rate according to the user-defined amount on the Rate
Control Settings screen.
30000
32000
sds/ac
sds/ac
30000
30000
30000
32000
Flow: 5280 sds/min
Applied: 501644.0 sds
Area: 19.17 ac
92B12
S46R1
Summary of Contents for ag leader
Page 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Page 2: ...Firmware Version 5 4 ...
Page 20: ...6 Firmware Version 5 4 ...
Page 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Page 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Page 56: ...42 Firmware Version 5 4 ...
Page 78: ...64 Firmware Version 5 4 ...
Page 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Page 84: ...70 Firmware Version 5 4 ...
Page 94: ...80 Firmware Version 5 4 ...
Page 108: ...94 Firmware Version 5 4 ...
Page 140: ...126 Firmware Version 5 4 ...
Page 154: ...140 Firmware Version 5 4 ...
Page 158: ...144 Firmware Version 5 4 ...
Page 162: ...148 Firmware Version 5 4 ...
Page 222: ...208 Firmware Version 5 4 ...
Page 244: ...230 Firmware Version 5 4 ...
Page 260: ...246 Firmware Version 5 4 ...
Page 290: ...276 Firmware Version 5 4 ...
Page 304: ...290 Firmware Version 5 4 ...