204
Firmware Version 5.4
M
ISCELLANEOUS
G
LOSSARY
OF
A
PPLICATION
S
ETTINGS
Configuration Settings
• Rate Outside of Field
Rate that will be used outside of the field boundary.
Zero
stops product application.
Last Good
uses the
previous rate before exiting the boundary.
Rx Default
uses the default rate written in the prescription file
loaded.
• Rate Display Smoothing
Determines how the feedback from the control channel’s rate sensor will be displayed on the run screen.
When checked, the system will display the target rate when the application rate is within 10% of the target
rate setting. When unchecked the system will display the raw feedback from the rate sensor.
• Minimum Flow
This setting is used to maintain a consistent spray pattern. The display will not allow flow to drop below the
entered setting. Set to flow at the lowest operating pressure for the selected spray tips with all sections on.
When spraying with one or more boom sections off, the system automatically reduces the minimum flow
setting according to the reduced spray width. To adjust this setting, Press
and enter the desired
numeric value.
• Controller Time Delay
Compensates for any delay in the control system when changing between different product flow rates
during variable rate application.
Speed Input Settings
• Primary Speed Source
Main speed input source used by the display.
• Backup Speed Source
If the primary speed source fails, the display will use the backup if one is available.
• Manual Speed
If both of the speed input sources are unavailable, manual speed can be used in order for the control
channel to provide application. Manual speed setting is for use during static machine testing or by the
control system in the absence of primary and backup speed signals.
Automatic Swath Control Settings
• Turn-On Look-Ahead
Determines how far ahead the system looks to turn the swath sections back on. This setting compensates
for any delay in the product control system when the sections are turned on.
• Turn-Off Look-Ahead
Determines how far ahead the system looks to turn the swath sections off. This setting compensates for
delay in the product control system when the boom sections are turned off.
• Outside Boundary Option
Determines the behavior of the sections when exiting the field boundary or prescription-mapped area.
Summary of Contents for ag leader
Page 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Page 2: ...Firmware Version 5 4 ...
Page 20: ...6 Firmware Version 5 4 ...
Page 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Page 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Page 56: ...42 Firmware Version 5 4 ...
Page 78: ...64 Firmware Version 5 4 ...
Page 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Page 84: ...70 Firmware Version 5 4 ...
Page 94: ...80 Firmware Version 5 4 ...
Page 108: ...94 Firmware Version 5 4 ...
Page 140: ...126 Firmware Version 5 4 ...
Page 154: ...140 Firmware Version 5 4 ...
Page 158: ...144 Firmware Version 5 4 ...
Page 162: ...148 Firmware Version 5 4 ...
Page 222: ...208 Firmware Version 5 4 ...
Page 244: ...230 Firmware Version 5 4 ...
Page 260: ...246 Firmware Version 5 4 ...
Page 290: ...276 Firmware Version 5 4 ...
Page 304: ...290 Firmware Version 5 4 ...