266
Firmware Version 5.4
3. Input Header Offset
For combines with offset headers, this compensates for the distance between the center of the
vehicle, and the center of the header's swath.
4. Perform a Vibration Calibration
The vibration calibration is used to compensate for the amount of force that is measured by the flow sensor
with no grain flow. For more information, see
“Vibration Calibration” on page 267
5. Calibrate Temperature
This sets the temperature offset to provide a correct moisture reading. For more information, see
“Temperature Calibration” on page 268
6. Calibrate Moisture
This sets the moisture offset to help provide accurate moisture and yield readings. For more information,
see
“Moisture Calibration” on page 268
7. Calibrate Grain Weight
A correct Grain Weight Calibration provides accurate readings across all grain flow ranges. Calibration is
required each year and for each grain type. For more information, see
C
ALIBRATE
D
ISTANCE
If you are not using GPS for ground speed, then after you have created a configuration you must
calibrate the ground speed input for accurate speed and area calculations. If you are using GPS, it is
recommended to calibrate distance in the event of GPS loss. Use the following procedure to calibrate
distance:
Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your
specific configuration > Setup (wrench) button > Speed Input button > Calibrate Distance
Follow the instructions shown on the screen.
Note: Calibration settings can be manually adjusted if desired by pressing button above Pulses/100 ft and
making small changes to the setting.
Calibrate Header Sensor
Prior to logging harvest data, you must calibrate the header sensor. Crops must be set up within the
system to proceed with the calibration routine.
Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your
specific configuration > Setup (wrench) button > Calibrate Header Sensor button
Follow the instructions shown on the screen.
Configuration
Select Your Specific
Configuration
Speed Input
Calibrate Distance
Configuration
Select Your Specific
Configuration
Calibrate Header Sensor
Summary of Contents for ag leader
Page 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Page 2: ...Firmware Version 5 4 ...
Page 20: ...6 Firmware Version 5 4 ...
Page 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Page 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Page 56: ...42 Firmware Version 5 4 ...
Page 78: ...64 Firmware Version 5 4 ...
Page 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Page 84: ...70 Firmware Version 5 4 ...
Page 94: ...80 Firmware Version 5 4 ...
Page 108: ...94 Firmware Version 5 4 ...
Page 140: ...126 Firmware Version 5 4 ...
Page 154: ...140 Firmware Version 5 4 ...
Page 158: ...144 Firmware Version 5 4 ...
Page 162: ...148 Firmware Version 5 4 ...
Page 222: ...208 Firmware Version 5 4 ...
Page 244: ...230 Firmware Version 5 4 ...
Page 260: ...246 Firmware Version 5 4 ...
Page 290: ...276 Firmware Version 5 4 ...
Page 304: ...290 Firmware Version 5 4 ...