CONNECTIONS
Pulse Input
The pulse input connector supplies 12 volts DC to the coin validator and accepts a
pulse stream from the coin validator. Several adaptor cables are available for
different coin validators
1
2
3
4
5
+ 1 2 3 4
12V Fan
12V Lamps
12V Lamps
12V Lamps
+
-
35
35
1
2
3
+ P -
Programmed 12V Output
This connector supplies a co12V output from pin 1 with 4 switched ground
returns. One for each of the 4 switching channels. These ground returns are open
collector transistor switches.
Up to 4 groups of low power 12V lights can be connected and will be controlled by
the light chaser. Output 4 is a special case and may be connected to a 12 V fan.
Make sure the total current consumption of all the connected lamps etc. does not
exceed 2.4amps. Shown below is a typical configuration.
Caution:
Improper connection may cause damage to the unit.
2K2
MicroCoin
Typical coin validator
connection for Low
pulses.
Gnd
Acc (Pulse Output)
+12VDC
2330 - SCORPION OPERATOR MANUAL
Summary of Contents for SCORPION 2330