background image

 

Vertex™ 

Rx-Z Series Zeolite Reactor Instruction Manual

   

           

        

©Vertex Aquaristik ™ 2018

  

 

 

 

P

ag

e

 

-

 

 

Do not exceed 

the recommended amount of media for your system’s net water volume. It is 

recommended to start at half dose and increase gradually to the desired amount over a period 
of time. Rapid changes in water chemistry can negatively affect your systems inhabitants. 

 

Always follow manufacturer guidelines for any dosing of probiotic media or additives. Vertex 

Aquaristik™  cannot  be  held  accountable  for  any  damages  excess  flow  through  the  reactor, 

excess use of zeolite media and/or additives dosed can cause. If you are unsure of the proper 
amount of flow and/or media required, contact the manufacturer directly.  

 

Vertex™ Rx

-Z reactors are supplied with an on-board dosing port. Check with your manufacturer 

if  it  is  recommended  to  dose  the  said  additive  directly  inside  the  reactor  and  at  what 
recommended dosage amount for your system.  

 

Zeolite media will be exhausted in time and needs to be exchanged. For proper media renewal 
regimens, please consult with the media manufacturer.  

 

To exchange the media: 
 

A-

 

Turn  the  pump  off  and  disconnect  from  power.  Do  not  attempt  to  service  or  perform 
maintenance on the unit when connected to power.  

B-

 

Tilt the lid back and forth in an upward motion and open the unit.  

C-

 

Remove the inner chamber. It is not necessary to disassemble the handle.  

D-

 

Loosen the screw attached to the top perforated plate using a flat head, soft tipped screw driver 
and move the plate up to allow easy removal of the exhausted media.  

E-

 

Replace the media based on the manufacturer’s recommendation. 

 

F-

 

Move down the perforated plate in place.  

G-

 

Tighten  the  screw  attached  to  the  top  perforated  plate  using  a  flat  head,  soft  tipped  screw 
driver. Refrain from over tightening.  

H-

 

Insert the inner chamber back inside the unit.  

I-

 

Tighten the lid and make sure all connections and unions are properly assembled.  

J-

 

Turn the unit back on and ensure proper flow for the amount of media being utilized.  

 

Maintenance: 
 

After extended operation time or when deemed necessary, lubrication can be applied on the O-rings. 
Only use food grade silicone grease.  
 
Unit can be fully disassembled for cleaning and/or maintenance. Refer to the assembly instruction of 
this guide before putting the unit back in operation.  
 
For any maintenance required on th

e pump, please refer to the Eheim™ instruction manual supplied.

 

 
 
 
 

Reviews: