2015/5/6V1.2+V1.1
31
key.
E6
The lifting motor is
abnormal.
Replace the lifting
motor or key.
E01
The voltage of frequency
converter is low.
Replace the filter,
high inductance and
frequency converter.
Inspect whether
the commercial
power is
(110/220V).
E02
The temperature sensor
of frequency converter is
abnormal.
Replace the
frequency converter.
E04
The frequency converter
outputs overcurrent.
Add lubricating oil in
the running machine
and replace
frequency converter.
E06
The frequency converter
has overcurrent.
Replace the braking
resistance of
frequency converter.
E08
The frequency converter
is grounded abnormally.
Replace the
frequency converter.
E21
The frequency converter
is in flash fault.
Replace the
frequency converter.
E22
The frequency converter
is in flash fault.
Replace the
frequency converter.
E28
The frequency converter
displays low voltage
warning.
Replace the filter,
high inductance and
frequency converter.
Inspect whether
the commercial
power is
(110/220V).
E37
The frequency converter
displays emergency stop.
Replace the
frequency converter,
control line and
electronic meter.
E09
The frequency converter
is overheat.
Add lubricating oil in
the running machine
and replace
frequency converter.
E0A
The overload of
frequency converter
motor is abnormal.
Replace the motor or
frequency converter.
Summary of Contents for T22.1