Basic Programming
6
-
5
Chapter 6: Starting the SBX IP 320
SBX IP 320 Installation Guide
Pre-Programming
Location PGM - Nation Code and Site Name (PGM 100)
Note:
The 4th pole of the DIP switch (SW1) on the MBU must be turned ON.
Nation Code
To program the Nation Code, perform the following steps:
1.
Press the [TRANS/PGM] PGM number (100) then [FLEX1] + 1 [Nation Code
for United States].
2.
Press the [HOLD/SAVE] button to accept the change.
3.
Now Reset the SBX IP 320 to initialize the Database for Nation.
4.
Set the 4th pole (SW1) of the MBU OFF when the System operates normally, to protect
programmed features.
Site Name
1.
Press the [TRANS/PGM] Enter Site Name (use the following DKT Map, Max.
23 characters allowed), then press [FLEX 2].
2.
Press the [HOLD/SAVE] button to accept the change.
. – 13
Q – 11
Z – 12
1 – 10
A – 21
B – 22
C – 23
2 – 20
D – 31
E – 32
F – 33
3 – 30
G – 41
H – 42
I – 43
4 – 40
J – 51
K – 52
L – 53
5 – 50
M – 61
N – 62
O – 63
6 – 60
P – 71
Q – 72
R – 73
S – 74
7 – 70
T – 81
U – 82
V – 83
8 – 80
W– 91
X – 92
Y – 93
Z – 94
9 – 90
Blank –
½
1
: –
½
2
, –
½
3
0 – 00
Summary of Contents for SBX IP 320
Page 1: ...Installation Guide SBX IP 320 ...
Page 4: ......
Page 40: ...Expansion KSU Installation 3 22 Chapter 3 KSU Installation SBX IP 320 Installation Guide ...
Page 58: ...Other Board Installations 4 18 Chapter 4 Board Installation SBX IP 320 Installation Guide ...
Page 84: ...Basic Programming 6 16 Chapter 6 Starting the SBX IP 320 SBX IP 320 Installation Guide ...
Page 100: ...Starting S W Upgrade 8 8 Chapter 8 Software Upgrade SBX IP 320 Installation Guide ...
Page 142: ... Data Display Area 9 42 Chapter 9 Remote Diagnostics SBX IP 320 Installation Guide ...