System Application Guide
SAG582136800
Spec. No. 582136800 (Model 502
NGFB
)
Revision BA, April 8, 2020
Page 17 of 129
List 3: 23” Main Shelf
Features
♦
Consists of one (1) 2RU high by 23” wide shelf.
♦
Includes AC input connectors and bulk output rear bus bars.
♦
Houses up to five (5) Rectifier Modules and one (1) Controller.
♦
For additional capacity, see List 4.
Ordering Notes
1)
Order List 3 as required. Also order the following as required.
2)
Order up to five (5) Rectifier Modules (P/N
) per List 3.
3)
Order one (1) optional Rectifier Module Mounting Position Blank Cover Panel (P/N PSK4830R-1) for each empty rectifier
module mounting position in the system if required.
4)
) Controller per List 3. Also specify appropriate configuration file for your site.
5)
Order one (1) IB2 Interface Board Assembly, (P/N
) per List 3 if required.
6)
Order up to two (2) Temperature Probes (
) as required. See “Optional Temperature Probes” on page 68 for
temperature probe options with a mounting tab.
7)
Order Relay Rack Anchor Kit(s) (
) as required.
8)
Order
section.
9)
Order
AC Input Cables and Line Cords
section.
10)
Order
section.
11)
Order output lugs per
under
section.
List 4: 23” Expansion Shelf
Features
♦
Consists of one (1) 2RU high by 23” wide shelf.
♦
Includes AC input connectors and bulk output rear bus bars.
♦
Houses up to six (6) Rectifier Modules.
Restrictions
Requires one (1) List 3.
A maximum of four (4) List 4 expansion shelves can be used with one (1) List 3.
A List 4 MUST be mounted directly beneath List 3 or another List 4 (for CAN bus connection).
Customer wiring must connect the DC outputs of List 3 and all List 4’s in a system in parallel.
Ordering Notes
1)
Order List 4 as required. Also order the following as required.
2)
Order up to six (6) Rectifier Modules (P/N
) per List 4.
3)
Order one (1) optional Rectifier Module Mounting Position Blank Cover Panel (P/N PSK4830R-1) for each empty rectifier
module mounting position in the system if required.
4)
Order
AC Input Cables and Line Cords
section.
5)
Order output lugs per
section.
List 5: 19” Assembled System with One (1) Main Shelf and AC Input / Bulk DC Output
Termination Panel
Features
♦
Consists of one (1) 2RU high by 19” wide rectifier shelf and one (1) 2RU high by 19” termination panel (pre-assembled for
4RU total).
♦
Termination panel includes AC input and DC output Bus bars.
♦
System houses up to four (4) Rectifier Modules and one (1) Controller.
♦
A screw-type terminal block is provided for connection of a battery and a load remote shunt.