SAG582136800
System Application Guide
Revision BA, April 8, 2020
Spec. No. 582136800 (Model 502
NGFB
)
Page 16 of 129
LIST DESCRIPTIONS
List Numbers
List 1: 19” Main Shelf
Features
♦
Consists of one (1) 2RU high by 19” wide shelf.
♦
Includes AC input connectors and bulk DC output rear bus bars.
♦
Houses up to four (4) Rectifier Modules and one (1) Controller.
♦
For additional capacity, see List 2.
Ordering Notes
1)
Order List 1 as required. Also order the following as required.
2)
Order up to four (4) Rectifier Modules (P/N
) per List 1.
3)
Order one (1) optional Rectifier Module Mounting Position Blank Cover Panel (P/N PSK4830R-1) for each empty rectifier
module mounting position in the system if required.
4)
) Controller per List 1. Also specify appropriate configuration file for your site.
5)
Order one (1) IB2 Interface Board Assembly, (P/N
) per List 1 if required.
6)
Order up to two (2) Temperature Probes (
) as required. See “Optional Temperature Probes” on page 68 for
temperature probe options with a mounting tab.
7)
Order Relay Rack Anchor Kit(s) (
) as required.
8)
Order
section.
9)
Order
AC Input Cables and Line Cords
section.
10)
Order
section.
11)
Order output lugs per
section.
12)
Order one (1) standard mounting bracket kit (P/N
) or one (1) optional Knurr data cabinet flush mounting bracket
kit (P/N
), as required. See descriptions under the “Accessory Descriptions” section.
List 2: 19” Expansion Shelf
Features
♦
Consists of one (1) 2RU high by 19” wide shelf.
♦
Includes AC input connectors and bulk output rear bus bars.
♦
Houses up to five (5) Rectifier Modules.
Restrictions
Requires one (1) List 1.
A maximum of five (5) List 2 expansion shelves can be used with one (1) List 1.
A List 2 MUST be mounted directly beneath List 1 or another List 2 (for CAN bus connection).
Customer wiring must connect the DC outputs of List 1 and all List 2’s in a system in parallel.
Ordering Notes
1)
Order List 2 as required. Also order the following as required.
2)
Order up to five (5) Rectifier Modules (P/N
) per List 2.
3)
Order one (1) optional Rectifier Module Mounting Position Blank Cover Panel (P/N PSK4830R-1) for each empty rectifier
module mounting position in the system if required.
4)
Order
AC Input Cables and Line Cords
section.
5)
Order output lugs per
section.
6)
Order one (1) standard mounting bracket kit (P/N
) or one (1) optional Knurr data cabinet flush mounting bracket
kit (P/N
), as required. See descriptions under the “Accessory Descriptions” section.