SAG582136800
System Application Guide
Revision BA, April 8, 2020
Spec. No. 582136800 (Model 502
NGFB
)
Page 18 of 129
Restrictions
System is non-expandable.
Ordering Notes
1)
Order List 5 as required. Also order the following as required.
2)
Order up to four (4) Rectifier Modules (P/N
) per List 5.
3)
Order one (1) optional Rectifier Module Mounting Position Blank Cover Panel (P/N PSK4830R-1) for each empty rectifier
module mounting position in the system if required.
4)
) Controller per List 5. Also specify appropriate configuration file for your site.
5)
Order one (1) IB2 Interface Board Assembly, (P/N
) per List 5 if required.
6)
Order up to two (2) Temperature Probes (
) as required. One probe is used with the Battery Charge
Temperature Compensation feature, the other to monitor ambient temperature. See “Optional Temperature Probes” on
page 68 for temperature probe options with a mounting tab.
7)
Order Relay Rack Anchor Kit(s) (
) as required.
8)
Order
section.
9)
Order
AC Input Cables and Line Cords
section.
10)
Order
section.
11)
Order output lugs per
under
section.
List 6: 19” Assembled System with One (1) Main Shelf, One (1) Expansion Shelf, and
AC Input / Bulk DC Output Termination Panel
Features
♦
Consists of two (2) 2RU high by 19” wide rectifier shelves and one (1) 2RU high by 19” termination panel (pre-assembled
for 6RU total).
♦
Termination panel includes AC input and DC output Bus bars.
♦
System houses up to nine (9) Rectifier Modules and one (1) Controller.
♦
A screw-type terminal block is provided for connection of a battery and a load remote shunt.
Restrictions
System is non-expandable.
Ordering Notes
1)
Order List 6 as required. Also order the following as required.
2)
Order up to nine (9) Rectifier Modules (P/N
) per List 6.
3)
Order one (1) optional Rectifier Module Mounting Position Blank Cover Panel (P/N PSK4830R-1) for each empty rectifier
module mounting position in the system if required.
4)
) Controller per List 6. Also specify appropriate configuration file for your site.
5)
Order one (1) IB2 Interface Board Assembly, (P/N
) per List 6 if required.
6)
Order up to two (2) Temperature Probes (
) as required. See “Optional Temperature Probes” on page 68 for
temperature probe options with a mounting tab.
7)
Order Relay Rack Anchor Kit(s) (
) as required.
8)
Order
section.
9)
Order
AC Input Cables and Line Cords
section.
10)
Order
section.
11)
Order output lugs per
section.
List 7: 23” Assembled System with One (1) Main Shelf and AC Input / Bulk DC Output
Termination Panel
Features
♦
Consists of one (1) 2RU high by 23” wide rectifier shelf and one (1) 2RU high by 23” termination panel (pre-assembled for
4RU total).