System Application Guide
SAG582136800
Spec. No. 582136800 (Model 502
NGFB
)
Revision BA, April 8, 2020
Page 23 of 129
Restrictions
When equipped with a 2-row Distribution Cabinet, the system is expandable by one (1) rectifier shelf in the field (List 14).
Ordering Notes
1)
Order List 16 as required. Also order the following as required.
2)
Order up to fourteen (14) Rectifier Modules (P/N
) per system.
3)
Order one (1) optional Rectifier Module Mounting Position Blank Cover Panel (P/N PSK4830R-1) for each empty rectifier
module mounting position in the system if required.
4)
) Controller per system. Also specify appropriate configuration file for your site.
5)
Order one (1) Distribution Cabinet (List
) per system.
6)
Order Battery Trays (
) as required.
7)
Order Relay Rack Anchor Kit(s) (
) as required.
8)
Order up to two (2) Temperature Probes (
) as required. See “Optional Temperature Probes” on page 68 for
temperature probe options with a mounting tab.
9)
Order
section.
10)
Order
AC Input Cables and Line Cords
section.
11)
Order
section.
12)
Order output lugs per
section.
List 17: 23” Assembled System with One (1) Main Shelf, Two (2) Expansion Shelves,
and Space for One (1) Distribution Cabinet
Features
♦
Consists of three (3) 2RU high by 23” wide rectifier shelves and interface for pre-assembled distribution.
♦
Includes AC input connectors.
♦
System accepts up to seventeen (17) Rectifier Modules, one (1) Controller, and one (1) Distribution Cabinet.
♦
Includes IB2 Interface Board.
Restrictions
The system is expandable by one (1) rectifier shelf in the field (List 15).
Ordering Notes
1)
Order List 17 as required. Also order the following as required.
2)
Order up to seventeen (17) Rectifier Modules (P/N
) per system.
3)
Order one (1) optional Rectifier Module Mounting Position Blank Cover Panel (P/N PSK4830R-1) for each empty rectifier
module mounting position in the system if required.
4)
) Controller per system. Also specify appropriate configuration file for your site.
5)
Order one (1) Distribution Cabinet (List
) per
system.
6)
Order Battery Trays (
) as required.
7)
Order Relay Rack Anchor Kit(s) (
) as required.
8)
Order up to two (2) Temperature Probes (
) as required. See “Optional Temperature Probes” on page 68 for
temperature probe options with a mounting tab.
9)
Order
section.
10)
Order
AC Input Cables and Line Cords
section.
11)
Order
section.
12)
Order output lugs per
section.
List 20: 19” Assembled System with One (1) Main Shelf and Space for One (1) GMT
Distribution Panel and One (1) Distribution Cabinet
Features
♦
Consists of a 2RU high by 19” wide rectifier shelf, and interface for pre-assembled distribution.