2.2 Features
•
Flexible extension of capacity, up to 15 or 20 kVA modular power, depending upon frame rating
•
N + 1 redundancy, improving availability
•
Modular design, modules hot-swappable by user
•
Intelligent battery management
•
External large batteries can be connected
•
Internal automatic and manual bypass
•
Transformer-based UPS frames provide output isolation transformer
•
Optional 10-A battery charger module
•
Continuous system monitoring
•
User-friendly interface with audible alarms and event logs
•
Supporting hot-pluggable and online update
•
Compatible with backup generators
Standard Components
•
UPS frame
•
User-interface module for comprehensive user indications and programmable controls
•
System-control modules and system-monitor module for system monitoring and
communications
•
Power modules for power conditioning
•
Battery modules for back-up power
•
Charger module option for charging batteries and long run-time applications
•
External battery cabinet prolongs system run time
Communications
•
Dry contacts
•
Liebert IntelliSlot communication ports
•
USB port
2.3 Major Components
This section provides a general description of each component and its functions. Please review this
section carefully, as it will give you a better understanding of how the UPS operates.
2.3.1 UPS Frame
All UPS components are located in the Liebert APS frame. The front of the UPS consists of a series of
plastic bezels. Grasp the bezels from the sides and pull straight out to remove the bezel and reveal the
battery/power-module bays. The standard-model frame provides cooling fans and a manual-bypass
breaker on the top. The transformer-model frame provides a manual-bypass breaker on its bottom and
fans on both top and bottom. The user-interface module is located above the power/battery-module bays
for easy access, operation and for viewing UPS operating information. On the lower-right of the user-
interface module are the system-control module bays.The UPS frames are shown in Figure 2.5 below.
NOTE: In the figure, the power module and battery module are extended for illustration purposes only.
Extending more than one module at a time could cause the unit to tip over.
Vertiv
| Liebert® APS™ Installer/User Guide |
16
Summary of Contents for Liebert APS series
Page 1: ...Liebert APS 5 20 kVA Modular UPS Installer User Guide...
Page 6: ...Vertiv Liebert APS Installer User Guide 6...
Page 10: ...Vertiv Liebert APS Installer User Guide 10 This page intentionally left blank...
Page 50: ...Vertiv Liebert APS Installer User Guide 50 This page intentionally left blank...
Page 76: ...Vertiv Liebert APS Installer User Guide 76 This page intentionally left blank...
Page 80: ...Vertiv Liebert APS Installer User Guide 80 This page intentionally left blank...
Page 109: ......