background image

 

 

Vertiv™ NetSure™ 211 SERIES -48 VDC Battery Cabinet Installation & User Manual (Section 6023)

 

|

 

Rev. L 

26 

Figure 30:  

Securing the Batteries in the Cabinet 

 

Summary of Contents for NetSure 211 Series

Page 1: ...NetSure 211 SERIES 48 VDC Battery Cabinet Installation and User Manual Section 6023 Revision L Specification Number 541434 Model Number 211BC...

Page 2: ...cifically described in this document The products covered by this instruction manual are manufactured and or sold by Vertiv This document is the property of Vertiv and contains confidential and propri...

Page 3: ...ription 9 Batteries 9 Specifications 10 Installation 10 Important Safety Instructions 10 General Requirements 10 Mounting the Battery Cabinet 10 Relay Rack Method 11 Wall Method 11 Connecting Battery...

Page 4: ...ury if not avoided ANSI OSHA This admonition is not used for situations that pose a risk only to equipment data or service even if such use appears to be permitted in some of the applicable standards...

Page 5: ...o contacting any uninsulated surface or termination use a voltmeter to verify that no voltage or the expected voltage is present Check for voltage with both AC and DC voltmeters prior to making contac...

Page 6: ...t injury from accidental electrical arcs Use certified and well maintained insulated tools Use double insulated tools appropriately rated for the work to be performed Ensure that wrenches with more th...

Page 7: ...hould be done determine the hazard risk category and to select proper PPE This product is intended only for installation in a Restricted Access Location Only authorized and properly trained personnel...

Page 8: ...Vertiv NetSure 211 SERIES 48 VDC Battery Cabinet Installation User Manual Section 6023 Rev L 8 This page is intentionally blank...

Page 9: ...y chained as shown in Figure 7 to increase the reserve time However a maximum system current of 30 amps should be maintained regardless of the number of interconnected cabinets Figure 1 NetSure 211 Se...

Page 10: ...e sea level For elevations between 3 000 feet and 10 000 feet derate the maximum operating ambient temperature linearly Overall Dimensions Battery cabinet dimensions are illustrated in Figure 2 Figure...

Page 11: ...y rack with the provided 12 24 x 1 2 hex head thread forming screws six per side P N 218710500 and 12 ground washers three per side P N 215640600 Torque these connections to 35 0 in lbs Wall Method WA...

Page 12: ...dapter 4 Mount the battery cabinet to a wall through the two 0 406 diameter holes on the back of the cabinet as shown in Figure 6 If mounting to a stud wall secure the battery cabinet to the studs 5 E...

Page 13: ...e is no limit to the number of battery cabinets that can be connected together However a maximum system current of 30 A should be maintained regardless of the number of interconnected battery cabinets...

Page 14: ...l to use these alarm leads to connect the battery cabinet battery disconnect circuit breaker alarm into the power system alarm circuits NOTE Supplied with the battery cabinet is a yellow alarm lead as...

Page 15: ...ween the batteries Figure 8 Placing Enersys SBS15 Batteries 3 Connect all four Enersys batteries using supplied wires Part Number 541420 crimped with 12 10 AWG ring lug on each end as shown in Figure...

Page 16: ...es using the buckle strap that is bundled along with the cabinet Installing Fiamm 12SLA12 Batteries Procedure 1 Place the batteries inside the cabinet Refer to Figure 11 2 Insert a spacer between the...

Page 17: ...5 Refer to Securing the Batteries Using the Strap on page 25 for instructions on securing the batteries using the buckle strap that is bundled along with the cabinet Installing EaglePicher HE 12V12 7F...

Page 18: ...es 3 Connect all four EaglePicher batteries using supplied wires Part Number 541424 crimped with 12 10 AWG Faston receptacle on each end as shown in Figure 15 Figure 15 Connecting EaglePicher 12V12 7F...

Page 19: ...s bundled along with the cabinet Installing Eaglepicher HE 12V7 7FR Batteries Procedure 1 Place the batteries inside the cabinet Refer to Figure 17 2 Break each spacer at its score line and insert bet...

Page 20: ...nals 5 Refer to Securing the Batteries Using the Strap on page 25 for instructions on securing the batteries using the buckle strap that is bundled along with the cabinet Installing Enersys NP18 12FR...

Page 21: ...binet as shown in Figure 20 Figure 20 Placing the Rear Spacer 2 Take the 3 Inner Battery Spacers and break off the end portion of the spacer where indicated as shown in Figure 21 Figure 21 Break off I...

Page 22: ...left and one of the fast on lugged cables to the positive terminal off the battery Repeat for third and fourth batteries in the string See Figure 23 Figure 23 Attaching Fast on lug to the Remaining Ba...

Page 23: ...binet 6 Place inner battery spacer next to battery Make sure that the positive long lead cable is resting on the rear spacer See Figure 25 Figure 25 Placing Battery Spacer 7 Set second battery in cabi...

Page 24: ...door fastener tabs hanging down and attach the other end of the fast on lugged cable to the negative terminal on the third battery fast on terminal Attach the short wire from the breaker labeled negat...

Page 25: ...ure 28 Slipping the Strap into the Buckle 3 Then loop the strap into the outer slot of the buckle Refer to Figure 29 Figure 29 Looping the Strap into the Buckle 4 Pull again the strap to tighten 5 Rot...

Page 26: ...Vertiv NetSure 211 SERIES 48 VDC Battery Cabinet Installation User Manual Section 6023 Rev L 26 Figure 30 Securing the Batteries in the Cabinet...

Page 27: ...XED CONNECTOR INPUT FROM SUPPLEMENTARY BATTERY CABINETS PIGTAIL CONNECTOR OUTPUT TO POWER SHELF OR MAIN BATTERY CABINET ALARM LEADS TO POWER SHELF C NO NC CB BATT BATT BATT BATT SPACER SPACER SPACER F...

Page 28: ...re trade names trademarks or registered trademarks of their respective owners While every precaution has been taken to ensure accuracy and completeness here Vertiv Group Corp assumes no responsibility...

Reviews: