INSTALLATION
Choosing and Preparing a Location for the Enclosure
The pole-mounted cross-connect enclosures can be installed at any height. For ease of access, install the
enclosure at working level per local practices.
SAFETY!
In areas where damage could occur to enclosures mounted at ground level, such as alleys,
mount the enclosure below aerial cables, with adequate clearance for bending the stub at a 90o angle to
prepare the splice. A balcony may be installed for ease of access and to provide a safe working position
for field technicians.
Installing the Enclosure
DANGER!
Be sure the area above the hoisting operation is clear of power lines or obstructions. Also, be
sure to follow all local and company safety practices during lifting.
Perform the following steps to install an Aerial Ultracab Cross-Connect Enclosure:
1.
Drill a
11
/
16
-inch hole through the pole for the top bracket (see
Figure 5:
Top Pole-Mounting Bracket