Checkingthebrakeoillevel (03_11, 03_12)
The brake fluid reservoir has a sight glass «
A
» made of transparent (located into the
hole drilled in the handlebar cover, right side); the quantity of liquid that can be seen
inside the sight glass indicates the quantity of liquid in the reservoir. When sight glass
«
A
» is full, the level inside the reservoir exceeds the Min. mark. When it descends
even a little below the maximum level, the oil level is considered to be at Min. When
it is empty, the level is below the Minimum. The brake fluid level may fall due to wear
on the brake pads. Should the level be below the minimum, the Customer is advised
to contact an
Authorised Piaggio Service Centre
for a thorough check of the braking
system. Should level be restored, follow the instructions below. Remove the front
handlebar cover following instructions indicated in the «Front headlight assembly»
section, then unscrew the 2 screws «
B
», lift the cover of the brake fluid reservoir
«
C
» and add the necessary quantity of fluid (fluid must always be over the minimum
level).
Check these levels with the reservoir in a horizontal position, i.e. with the handlebars
straight and the scooter perfectly level.
CAUTION
TOP-UPS SHOULD ONLY BE CARRIED OUT WITH DOT4 CLASSIFIED BRAKE
FLUID.
DO NOT LET THE HIGHLY CORROSIVE BRAKE FLUID CONTACT PAINTED
PARTS. SHOULD THIS OCCUR, IMMEDIATELY WASH OFF WITH WATER.
BRAKING CIRCUIT FLUID IS HYGROSCOPIC, MEANING THAT IT ABSORBS
HUMIDITY FROM THE SURROUNDING AIR; IF THE HUMIDITY CONTAINED IN
THE BRAKE FLUID EXCEEDS A CERTAIN VALUE, THIS WILL RESULT IN INEF-
FICIENT BRAKING.
34
3 Maintenance
Summary of Contents for ET2 50
Page 4: ...4 ...
Page 6: ...6 ...
Page 7: ...Vespa ET2 50 Chap 01 Vehicle 7 ...
Page 14: ...01_11 01_12 14 1 Vehicle ...
Page 17: ...Vespa ET2 50 Chap 02 Use 17 ...
Page 27: ...Vespa ET2 50 Chap 03 Maintenance 27 ...
Page 49: ...Vespa ET2 50 Chap 04 Technicaldata 49 ...
Page 53: ...Vespa ET2 50 Chap 05 Sparepartsanda ccessories 53 ...
Page 55: ...Vespa ET2 50 Chap 06 Scheduledmaint enance 55 ...