103
9.2.11
Checking the Regulator
Connect the induction nippers of an ammeter to the
positive cable of the voltage regulator. Measure the
battery voltage and, after turning the lights on
without starting the engine, wait until voltage reading
settles at about 12V. Start the engine and measure
the current supplied by the system with the lights on
and the engine running at high speed.
If the supplied current is less than 10A, repeat the
test using a new regulator and/or stator.
Rs = Red, Ne = Black
9.2.12
Checking the Automatic Choke Section
For information on how to carry out the functional
and resistive check of the component, refer the
engine section of this manual. Regarding the
automatic choke device power supply, keep the
system connector attached and check that battery
voltage is present between the two terminals,
while
the engine is running
(see figure).
If there is no voltage, connect the multimeter
negative terminal to ground and the positive terminal
to the orange wire on the automatic choke devic e.
With the ignition switch turned onto the «ON»
position, check for the presence of battery voltage. If
no voltage is detected, check the wiring connected
with the ignition switch and the two fuses 15A (no.
8).
If voltage is present, repeat the check from the
ignition control unit connector.