20
■
Specifications
Specifications
Model
: G-9
Type
: High voltage applied type ionizing gun
Structure
: Direct coupled (Touch the electrode when applying current
may bring electric shocks.)
Ionizing method
: Alternating current corona discharge method
Applied voltage & Frequency
: AC 8 kV p-p (
±
5%) / 32kHz (Typ.)
Air pressure
: 0.5MPa (typ.)
Air pressure range
: 0.3
~
0.6MPa
Air consumption
: Approx. 200L/min (0.5MPa)
Blow air speed
: 12.3m/s (0.5MPa, 200L/min, 150mm)
Requirement air conditions
: Clean Dry Air (CDA) JIS B 8392-1:2012 2.6.3
No lubricants (Never use lubricated air)
Operating temperature & humidity
: 0
~
45
℃
/ 10
~
90
%
RH
(
without freezing or dew condensation
)
Storage temperature & humidity
: -30
~
50
℃
/ 10
~
90
%
RH
(
without freezing or dew condensation
)
Installation distance
: approx. 50 mm
~
300 mm
(from nose to working material)
Decay time
:
±
1000V
→±
100V
:
>1Sec. (0.5MPa
、
203L/min
、
150mm)
Ion balance
:
±
30V
Noise
: 104.8dBA
(
0.5MPa, 200L/min, 0.6m
)
83.1dBA
(
0.3MPa, 160L/min, 0.6m
)
77.7dBA
(
0.3MPa, 155L/min
、
0.6m, with an optional parts
G-9WN
)
Operationg conditions
: Indoor, Light industrial
Safety
: High voltage overload detecting / Auto shut down / Auto
reset
Air connector
: O.D. 8mm Air tube fitting
Material
: Body
…
Poly carbonate
Electrode
…
Tungsten
Nozzle
…
Poly carbonate
Mortor unit cover
…
poly carbonate
Dimensions
: See p.22 “External Dimensions”
Weight
: Approx. 474g