16
■
Specifications
Major Specifications
Model
: HPB series
Type
: High voltage applied type ionizing bar
Basic structure
: Direct coupled (electric shocks may be felt by touching
electrode needles during operation.)
Applied high voltage
power source
: High voltage power supply GP-1 *1
Method of ionizing
: Alternating current / corona discharging
Applied voltage / frequency
: AC 3.5 kV / 50 - 60 Hz (set / adjusted on GP-1)
Operating
temperature / humidity
: 0 - 45 °C / 10
~
85 %RH
(without freezing or dew condensation)
Storage
temperature /humidity
: 0 - 50 °C / 10
~
85 %RH
(without freezing or dew condensation)
Standard distance
to object material
: approx. 15 mm
~
100 mm
(electrode needle to object materials)
Decay time
: approx. 2 sec., at 100mm
Efficient neutralize current
: 1.6 μA / cm
Ion balance
: set/adjusted on GP-1 (CPM or equivalent will be needed)
Installation place
: Indoor / light industrial
Safety circuit
: High voltage outputs anomaly detection and automatic cut-off
function on the High Voltage Power Supply GP-1.
High voltage cable
: 3m *2, Silicone shielded cable
Connector
: High voltage connector CON-4
Materials
: Outer case; Aluminum
Inner case; Glass-fiber reinforced PBT
Electrode needle; Titanium
Pitch block; PBT
Cable block; Aluminum
Size
: See external dimensions (next page)
Weight
: Electrode bar; approx. 400 g / m HV cable; 360g (includes
connector)
Expected lifetime
: approx. 10,000hours as a guide (8hours×250days×5years).
* This is not a period of guarantee.
Options
: Air assist bar
AAB
*1 Use the power supply with the red "OUTPUT 4 kV" sticker.
See instruction manual of GP-1.
*2 The cable length can be changed as an option (total length of cable and bar should
be shorter than 9m for the GP-1).